SBIR/STTR Research Award

A High Resolution Imager for Tissue Specimen Radiography

Award identifier 7f744091c9fdcf2f0915051e85b0f124d2f3a47914e594b03133b7fe89957973Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,802

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
NOVA R&D, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
M95NX1TLX4N9
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Accurate assessment of tissue specimens is a key requirement in the diagnosis of breast cancer. This requires images with high spatial and contrast resolution. A compact, high-resolution x-ray system for imaging of excised tissue specimens will be developed for use in the operating room. Currently, specimen radiography is performed in a cabinet x-ray unit where the image is acquired either on radiographic film or using a small area digital detector. Typically, the digital detector includes an x-ray absorbing phosphor, a fiber-optic coupler and an optical CCD camera. Such a detection system is limited in spatial and contrast resolution related to the use of phosphor technology and distortion and losses in the fiber-optic components. The new system will employ a novel direct conversion selenium CCD detector that will be used to form a slot scanning x-ray imaging system. It offers high x-ray detection and conversion efficiency, high limiting spatial resolution, low noise, linear response and high dynamic range. In the proposed system, the incoming x-rays are absorbed in a layer of selenium where their energy causes electric charge to be liberated. The selenium is directly evaporated onto a CCD readout chip. The charge is integrated in the readout chip and the signal is then digitized and sent to a computer for image processing and display. In Phase I the research plan consists of five goals. First, a small version of the CCD chip will be used in an experimental scanning system to simulate the full-scale specimen radiography system. To emulate a full-scale system, composite or "stitched" images will be made from multiple scans with the small- format chip. Imaging will be performed on tissue-equivalent plastic test objects. Second, the optimal geometry for image acquisition will be determined. For example, depending on the angle and trajectory of the detector, distortions associated with parallax will potentially limit resolution. Third, the optimal x-ray spectral energy will be determined. Tube output, required imaging time, contrast and dynamic range for high quality images will be considered in the optimization. Once this is achieved, the fourth goal will be to evaluate the importance of scattered radiation on image quality through modeling of signal and noise transfer and through experimental imaging using tissue-equivalent phantoms. If necessary, an anti-scatter technique will be used to reduce scatter. Finally, based on the results of these experiments we will prepare a preliminary design of a prototype digital specimen imager system to be built during Phase II. During Phase II, the full-size optimized CCD readout chip will be fabricated and tested and then integrated into a selenium detector with optimized thickness. The new detector's imaging capability and performance will be characterized. The system is expected to provide improved definition of fine tissue structures and aid in determining that the targeted focus of disease has been appropriately removed in biopsy or surgery. This should help ensure improved accuracy of resection of disease and provide a better link between pre- operative imaging and tissue histology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

30 SBIR/STTR records share this UEI (1989–2009). Reported award amounts total $7,630,645. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, Department of Energy, Department of Transportation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.