SBIR/STTR Research Award

Water-Equivalent Plastic Scintillation Detectors for Small-Field Radiotherapy

Award identifier 99d4c029d4ce41df771c3ff9f688fd98c56b755724fb1bcd17e4bd4f56c8b5abAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$960,511

Program and phase

SBIR · Phase II

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
STANDARD IMAGING INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
EQENAAXF6AV1
Solicitation number
PA12-088
Topic code
NCI

Research abstract

DESCRIPTION (provided by applicant): Standard Imaging, Inc. is developing a new generation of radiation dosimeters for small field dosimetry. These small detectors are needed in clinical applications such as stereotactic radiosurgery/stereotactic radiotherapy (SRS/SRT), intensity modulated radiation therapy (IMRT), dynamic arc therapy, and tomotherapy treatments. The enabling technology is the point scintillation detector that employs a miniature plastic scintillator coupled to a color PIN diode detector via an optical fiber. Small field radiotherapy techniques such as stereotactic radiosurgery (SRS) or stereotactic body radiation therapy (SBRT) enable delivery of high radiation doses to tumors while sparing healthy tissue and organs at risk. These special and complex treatment modalities significantly benefit patients and offer substantial advantages over traditional radiotherapy techniques. Because SRS and SBRT treatments often deliver the entire therapeutic dose in a single or hypofractionated treatment regimen, the treatments must be delivered accurately. Phase I generated a robust, single-point water-equivalent scintillation dosimeter to accurately characterize and measure the dosimetry of small fields and to verify these special treatments before delivery. The compact, fully operational Plastic Scintillation Detector (PSD) is further enhanced when paired with Standard Imaging's dual-channel SuperMAX electrometer. However, the PSD/SuperMAX electrometer system cannot yet be used with water scanning systemsbecause it lacks a compatible analog signal output. Coordinated use of a water scanning system with SRS-appropriate detectors is crucial to characterize these precise radiation fields accurately and efficiently before patient treatment. The overall goal ofthis Phase II project is to transition th Phase I small-field detector from a bench-top system requiring a specialized 2-channel electrometer to a versatile fully commercialized medical radiation detector. Achieving this goal will advance the successful Phase I project by (1) greatly expanding the effectiveness and market potential of PSD devices by developing a universally compatible detector system that could be fully used in place of an ionization chamber or diode with existing medical radiation measurement equipment, especially water scanning systems, (2) thoroughly optimizing the detector, and (3) fully characterizing the detector for easy application in typical clinical settins. At the successful completion of this Phase II study, Standard Imaging will be poised to deliver to the market a well-characterized PSD suitable for precise dosimetry and QA of small fields used in SRS and SBRT, and that is fully compatible with existing measurement systems. Further development of this single-point system subsequently could include generating multi-point systems such as 2D arrays for patient dosimetry or fixed linear arrays for water scanning. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Patients undergoing very delicate radiation treatment, suchas stereotactic radiosurgery/ stereotactic radiotherapy (SRS/SRT), intensity modulated radiation therapy (IMRT), dynamic arc therapy, or tomotherapy treatments, need extremely precise and accurate doses. Current methods are adequate, but could be much better. Standard Imaging is developing a reliable, miniaturized Plastic Scintillation Detector (PSD) system that is easy-to-use, will accurately measure the actual radiotherapy dose and improve patient care and safety.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2010–2024). Reported award amounts total $3,205,902. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.