SBIR/STTR Research Award

Field Analytical Method for Perchlorate

Award identifier fb5a1e8a6f8c959e63eb49420d5eb337c830415370246e12794a808a53292936Awarding agency Environmental Protection Agency

Award amount

$70,000

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Environmental Protection Agency
Branch
Not reported
Recipient company
IA, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

Perchlorate is a widely-used component of solid fuel, missile and rocket propellants, explosives and pyrotechnics. It has been shown to reduce iodide uptake into the thyroid gland. The EPA has found Perchlorate contamination in 18 states and believes contamination may exist in as many as 39 states. In early January 2005, the National Academy of sciences, in an EPA-sponsored study, recommended a reference dose (RfD) for human ingestion of 0.7 µg/kg/day, which suggests a maximum contaminant level (MCL) of 24.5 µg/l (ppb) or lower, while several states allow between 1 and 6 µg/L. Based upon this recommendation, there is a need for field monitoring of Perchlorate in ground and surface waters to test the effluent of remediation facilities and to determine soil cleanup levels. To provide a field analytical method, we have devised a technology that combines ion chromatography (IC) , similar to that use in EPA Method 314, with specific Perchlorate detection using a low detection limit ion selective electrode (ISE). Use of the Perchlorate ISE as the detector results in lower interference form common anions than is found using Method 314. For this method, we received a patent in 2004 (U.S. Patent no 6,736,958). This method simplified and improved Method 314, as the ISE replaced both the conductivity detector and the suppression Unit. It also improved the approach of measuring Perchlorate by ISE, because the presence of sufficiently high levels of competing ions, measured without separation, can yield false positive results. The innovation of this Phase I research is to simplify and standardize electrode construction by casting the electrode on thin-walled, porous tubing having defined free space. The objectives are to 1) cast electrodes on a selection of porous tubing, selecting one which provide optimum robustness and reproducibility; 2) optimize electrode response by selecting the ionophore, plasticizer and other ISE components; and 3) determine the selectivity obtained when using the perchlorate ISE as the detector for IC. Phase II will focus on optimizing calibration, developing analytical software, and field testing a prototype instrument. The resulting instrument will be suitable for field use, adaptable to batch analysis in the lab, and capable of remote sensing. Potential markets include DoD contractors, environmental engineers and testing labs, state and municipal water authorities and remediation firms.

Technology keywords

Not reported

Agency intelligence

Environmental Protection Agency

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.