SBIR/STTR Research Award

Implantable Wire Harness with Flexible Linear Disconnect

Award identifier aa10b4c95521e1f81fa85f2e2399ccb4043f8c2f01e1a9b286d05ec1ab87dd6cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$229,748

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Pmi Industries, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
PCJNDLHJTD36
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Electro-mechanical circulatory assist devices such as ventricular assist devices (VADs) and Total Artificial Hearts (TAHs) have shown great promise for extending and improving the quality of life of patients who suffer from heart disease. Currently, electrical wiring harnesses with disconnects used with these systems for implantable use in the human body, suffer from basic problems such as fluid leakage, corrosion, material fatigue, etc. In addition to functional failures they are often too large and bulky becoming a source of discomfort for the patient. PMI intends to develop and design a smaller and flexible electro-mechanical connector that will resist leaks from surrounding body fluids, hence not corrode, and be robust and flexible in nature to the expected environment encountered during a fully implantable application. Dependence on a perfectly operating invasive electrical system is paramount to life. History has shown that connectors are the weak link in almost all electrical systems and remain so today in the artificial organ arena PMI will design and demonstrate a small implantable Wiring Harness with the Flexible Linear connector. The primary goal is to manufacture a workable sample and verify PMI's Flexible Linear Interconnect (FLI) performance against requirements set forth. Phase I will generate this design and provide demonstrated results of the non-leakage ability of the FLI and its robust nature in a simulated environment. Tests will be conducted to verify results. Phase II will generate a workable prototype for complete laboratory testing and eventual bovine implants.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.