Research abstract

Current oscillometric blood pressure monitors applied to neonates and children are primarily developed from extension and modification of an empirically based fixed ratio algorithm used in adults. However, because the fixed ratio algorithm does not count for patient specific arterial compliance and pressure waveform, the accuracy and reliability of the pressure measurement are still limited by variations of patient circulatory physiology from newborn infants to children. A key to addressing this problem is found in a physiologically based oscillometric method for noninvasive arterial pressure measurement; this method utilizes patient specific physiological information (compliance and waveform) from the same oscillogram as measured by the current oscillometric devices. Since the new method will incorporate physiological variation with a pressure measurement algorithm, accuracy and reliability of blood pressure values should be increased in proportion to the decreased influence of the physiological variations. Since the new method uses the same oscillogram information as the current oscillometric devices to calculate pressure values, it is logical to develop a new algorithm. The new algorithm will be based on the current device hardware, and we will upgrade its software in order to achieve the benefit of the new method while retaining the advantages of hardware design and operation strategy for the current devices. Therefore, reducing the cost for the new product development. It is, therefore, proposed to test and verify the expected improvement in accuracy and reliability of pediatric pressure measurement by applying the physiologically based oscillometric method.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.