SBIR/STTR Research Award

LIGHT EQUALIZATION RADIOGRAPHIC SCREEN/FILM CASSETTE

Award identifier 3929ecfa0c280f21c9a09d311d9e5ad0dd869fa39edff2d519fc5150d5927fedAwarding agency Department of Health and Human Services

Award amount

$492,935

Program and phase

SBIR · Phase II

Award year

1990

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Innovative Imaging Sciences
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE DEVELOPMENT OF A NOVEL ELECTRONIC SCREEN/FILM CASSETTE FOR USE IN MEDICAL X-RAY IMAGING (RADIOGRAPHY) IS PROPOSED. DURING PHASE I, A STANDARD CASSETTE WILL BE MODIFIED BY ADDING A TWO DIMENSIONAL ARRAY OF PHOTODETECTORS INTERDIGITATED WITH A SECOND ARRAY OF LIGHT EMITTING DIODES (LED'S), PLACED BEHIND THE BACK INTENSIFYING SCREEN. THE PHOTODETECTORS, ACTIVATED DURING A RADIOGRAPHIC EXPOSURE, WILL BE USED TO ESTIMATE THE REGIONAL X-RAY EXPOSURE RECEIVED OVER CONTIGUOUS 2-10 CM(2) REGIONS OF THE FILM. FOLLOWING THE TERMINATION OF THE X-RAY EXPOSURE, THE INTERDIGITATED ARRAY OF LEDS WOULD BE ACTIVATED MOMENTARILY,EACH DIODE DELIVERING AN ADDITIONAL AMOUNT OF LIGHT EXPOSURE, DETERMINED BY THE SIGNAL RECORDED BY NEARBY PHOTODETECTORS, SUCH THAT THE RESULTANT OPTICAL DENSITIES RECORDED ON A RADIOGRAPH, ONCE DEVELOPED, WOULD LIE ABOVE SOME PREDETERMINED THRESHOLD VALUE. USE OF THE PROPOSED CASSETTE WILL IMPROVE UPON CURRENT RADIOGRAPHIC FILM QUALITY IN THREE WAYS: 1. BY INCREASING IMAGE CONTRAST IN ORDINARILY UNDEREXPOSED REGIONS ("TOE") OF A NORMAL RADIOGRAPHIC FILM; 2. BY COMPRESSING THE RANGE OF OPTICAL DENSITIES RECORDED ON A NORMAL RADIOGRAPHIC FILM, AND; 3. BY REDUCING THE "RETAKE" RATE FOR SEVERELY UNDEREXPOSED RADIOGRAPHS. DURING PHASE II, SEVERAL PREPRODUCTION PROTOTYPE CASSETTES WILL BE CONSTRUCTED USING SEVERAL COMMONSCREEN/FILM TYPES AND EVALUATED IN A SERIES OF CLINICAL TESTS IN A VARIETY OF RADIOGRAPHIC PROCEDURES - CHEST, MAMMOGRAPHIC AND BONE RADIOGRAPHY.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.