SBIR/STTR Research Award

Portable Field Anesthesia Machine

Award identifier c2911945b7442c945e59c71b58d6da1f371bd713fd8cbcf279d8d3fa328e3a33Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Core Devices, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The need for a reliable and safe field anesthesia machine that is portable, lightweight, tippable, does not require compressed gas, easy to setup and maintain, insensitive to shock, and cost effective, has been expressed repeatedly by physicians devoted to civilian and military healthcare in the field. This is amplified by the growing trend towards ambulatory surgery, the global war against terrorism and requirements for appropriate medical devices to facilitate military and civilian casualty care, as well as healthcare needs in remote environments where physicians are constrained by the absence of suitable anesthesia equipment. Studies of combat and civilian surgical care shows that existing devices have not evolved to address the unique requirements of surgery outside of the traditional operating room. Evidence suggests that hemorrhage is the biggest cause of death in the battlefield, and that it can be minimized by stabilizing the patient prior to evacuation. The situations encountered in the field are austere and require anesthesia systems that will function reliably in extreme environmental conditions. In addition, since the last 32 years, there has been over a 50% increase in the number of surgeries performed on an outpatient basis, yet there are no anesthesia machines specifically designed for these surgical settings. Studies of patient trauma cases show that vaporizers are the second biggest contributor to patient trauma, second only to breathing circuits. They are unreliable if tipped or agitated and can deliver unsafe concentration of anesthetic gas to patients. We have invented a vaporizer that overcomes these drawbacks and propose to optimize it for potential commercialization through further development. Preliminary results are promising. Tests will be conducted on optimized prototypes under simulated physiologic conditions that mimic field operational environments.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.