SBIR/STTR Research Award

Rapid point of care HIV PCR diagnostic device

Award identifier d92bb2f0b7f04c3a0d25a859e445fe694f2c9fdf172d920e1c9a2dab38577feeAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,431

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MICRONICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Since the late 1980s national guidelines to confirm HIV-1 infection dictate the use of Western blot (WB) and indirect immunofluorescence assay (IFA) for diagnosis1. However, nucleic acid amplification tests (NAAT) may i dentify some infections earlier; reduce testing costs; permit HIV-2 and broader HIV-1 subtype detection; reduce provision of false-positive, false-negative, and indeterminate test results. NAAT is currently not recommended for screening since it is much mo re expensive and involves complex methodology. However, a low cost, rapid NAAT test at point of care would be useful in Sexually Transmitted Infection (STI) clinics or emergency rooms (where patients often do not return for tests results) or on labor and d elivery wards for high-risk pregnant women who have not previously been tested. More frequent screening in all health care settings could increase the proportion of HIV-infected clients who learn their results and who could be linked to appropriate care. M icronic's goal is to develop a firstof- its-kind, low cost qualitative PCR assay for HIV provirus DNA detection that is automated within a closed system, disposable device and allows specimen in / result out processing at near patient point of care and in low resource settings. The intent is to sell this device at under 5 as compared to the 45 to 75 current NAAT tests cost. The assay strategy is as follows : DNA is extracted from a whole blood finger stick (20-50 microliter) specimen using fluidic and va lve logic within a laminate polymer device and the eluted nucleic acid introduced directly into microchannels to rehydrate a dried PCR master mix. PCR is rapidly performed within the microchannels in under 10 minutes. The amplified product is fluorescently tagged by a FRET method and a positive result detected optically at the end of 40 thermal cycles. Successful completion of the phase I milestone of 10 copy HIV detection following device extraction and amplification will confirm the validity of our assay integration and closed device strategy. PUBLIC HEALTH RELEVANCE: In order to better identify and counsel persons with unrecognized HIV infection and link them to clinical and prevention services as well as further reduce perinatal transmission of HI V in the United States the CDC has recommended expanded screening. The most sensitive screening method is based upon detection of the nucleic acid testing but this approach is currently expensive and performed in reference laboratories. We propose the mini aturization and automation of nucleic acid testing methods to enable low cost, near patient testing.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.