SBIR/STTR Research Award

Cryocooled Biomagnetometer

Award identifier 4a440b1b96c77d8034ae8167ceefefaf5c230d0db8b56a3f2ceaf760fd4079feAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$87,601

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRISTAN TECHNOLOGIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Z2E6MXZKNGK9
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): We propose to study and determine the feasibility of developing a novel approach for a cryocooled multichannel large biomagnetic system. Mechanical refrigeration is the only technique capable of providing the economical gains involved in cooling large biomagnetic systems. The proposed design would make these systems more economically attractive to run and maintain as well as reducing the logistics associated with constant handling of liquid helium. Biomagnetometers insta llations based on SQUID operation have always required liquid cryogens to operate. Typically this operation can run a cost in the range from 0.5 - 2.5 million dollars depending on the type of system and number of detection channels. Thus a typical MEG i nstallation will consume 20,000 - 40,000 of liquid helium annually. While the economics of liquid helium have not been a major inhibitor to the diffusion of biomagnetic instrumentation in the past, scarcity and increasing costs could change that. Mechanic al closed cycle refrigerators has become an alternative to the use of liquid cryogens. These include reduction of operating costs, use in remote locations, and operation in non-vertical orientations, avoiding interruptions in cryogen deliveries, safety, an d the convenience of not having to transfer every few days. There are two main obstacles to using closed cycle refrigeration with SQUIDs. The first is the mechanical movement that (ultimately) causes the detection coils to move in the Earth's magnetic fiel d. The second is the magnetic signature due to the moving parts of the cryocooler's cold head and compressor. The proposed design could significantly increase the market for large biomagnetometer systems not only in the US but also especially in European a nd Asian countries because of the lack of foreign helium gas source causing the associated costs to be twice the US costs. In addition, a helium shortage is developing due to increasing demand in industrial.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

32 SBIR/STTR records share this UEI (1989–2021). Reported award amounts total $12,834,417. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.