SBIR/STTR Research Award

FLOW MEASUREMENT AT DIALYSIS ACCESS SALVAGE

Award identifier 492cb8cae8dfe950be7e5cb0cf748e858234392ffc10d5aee545cffb8eeba515Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$0

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRANSONIC SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
JYLFZBGCEVB6
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Over 100,000 PTFE graft angioplasties are performed in America each year to restore adequate access flow, but up to 50% of the procedures must be repeated within three months. Radiologist now derive interventional efficacy from pressure and vessel diameter measurements. Direct measurement of volume flow (ml/min) would give immediate feedback on procedural success. Transonic Systems proposes to resolve this need by further developing and commercializing an inexpensive catheter-based AngioFlowmeter for measuring blood flow during angioplasty of PTFE grafts and native fistulae. Our Phase-I clinical studies demonstrated that access flow may be measured accurately and repeatably using thermodilution catheters introduced through the angioplasty antegrade sheath and room temperature saline injections. Our Phase-ll plans are to: Attain FDA clearance. Refine and validate the catheter designs and measurement algorithms for catheter placement through antegrade and retrograde introducer sheaths; Refine and validate algorithms to identify whether the flow-limiting stenosis is on the graft arterial or venous side; Demonstrate the system's efficacy in controlled clinical trials; Publish results of the study in preparation for market introduction. At the end of Phase II, Transonic Systems aims to market the AngioFlowmeter as a new quality assurance tool for interventional radiology procedures. PROPOSED COMMERCIAL APPLICATION: An access flow measurement catheter would have routine use during radiological and surgical interventions to restore flow. It would allow quantitative assessment of the efficacy of percutaneous angioplasty and thus support improved outcomes. This may in turn reduce the need for repeat interventions, improve the quality of life for ESRD patients, and reduce healthcare costs in the US by $18 million/year. We aim to market this device to surgical and interventional radiology and interventional radiology suites worldwide.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

22 SBIR/STTR records share this UEI (1987–2020). Reported award amounts total $8,451,413. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.