SBIR/STTR Research Award

A High-Performance Quiet Head Gradient Coil for High-field MRI

Award identifier 29f324d9886903756ee98366c3566823b345e58867630dd213ce193eec9f4980Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$199,384

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DOTY SCIENTIFIC, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
ZEWHLT5Y7H33
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Compared to current practice with whole-body-gradient coils, an advanced head gradient coil promises over twice the gradient strength (for higher resolution) and at least three times higher slew rates (for faster imagi ng sequences), with an order of magnitude reduction in nerve stimulation and greatly reduced acoustic noise. The potential usefulness of a high-performance head gradient coil has been widely recognized for more than a decade, and many groups around the wor ld have each put millions of dollars into attempting to developing a satisfactory solution, but to limited avail. The enormous increases in S/N in head MR RF coils reported over the past year serve to further strengthen the justification for a high-perform ance dedicated head gradient coil. Preliminary simulations indicate that an optimal combination of a number of improvements in our pre- vious crescent-coil approach will permit the realization of a practical, robust, head gradient coil with dramatically re duced acoustic noise, higher gradient strength, and substantially reduced manufacturing cost. The higher gradient performance is especially needed at higher fields for improved brain functional imaging (fMRI). The primary justification in clinical applicat ions may be the improved S/N that will be obtained in Diffusion Weighted MRI techniques. Next-generation ultra-fast hyperpolarized 13C techniques will also benefit. Moreover, a dedicated head MR scanner would be less expensive than a whole body scanner whi le providing greatly improved performance for head and extremity applications in patients of all ages, and for whole-body imaging of infants. Such a system could supplant x-ray CT in more cases. Based on preliminary simulations, the following performance i s expected: 200 mT/m gradient at 900 A; slew rate of 520 T/m/s at 1400 V; 25 cm Region of Uniformity imaging diameter with 10% rms non-uniformity; residual eddy current effects under 0.4%; acoustic noise below 100 dB for a typical EPI brain sequence in a 3 T field; and mechanical robustness suitable for operation with no current de-rating at fields at least up to 8 T. The RT shims will provide major corrections through Z4, including dynamic Z0 and Z2. The Phase I will complete detailed simulations and balan ced optimization of all parameters. A prototype coil will be constructed, and preliminary tests will be completed. More extensive testing will be carried out during Phase II at another institution, followed by revisions based on lessons learned and constru ction and testing of the pre-production version.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

44 SBIR/STTR records share this UEI (1985–2025). Reported award amounts total $25,710,711. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.