SBIR/STTR Research Award

Ultrahigh speed and resolution OCT/OCM using broadband swept VCSEL technology

Award identifier 4bebf7c000e6e7b78e280f3c9aa545ef4c47c22c930b55f2268ec14e659376e1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,180,420

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PRAEVIUM RESEARCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
UEN4RJGPDNR4
Solicitation number
PHS2010-2
Topic code
NCI

Research abstract

DESCRIPTION (provided by applicant): The ultimate goal of this effort is to develop, validate, and commercialize an ultra-broad tuning range, ultrahigh scan rate, swept laser source imaging engine that will enable the next generation of Optical Coherence Tomography / Optical Coherence Microscopy (OCT/OCM) systems. OCT and OCM enable 3D in vivo volumetric imaging of tissue pathology by detecting the echo time delay of back-reflected and backscattered light. OCT and OCM have powerful advantages as a cancer imaging modality because they provide information on tissue pathology in real time, without the need to excise and process specimens as in conventional excisional biopsy and histopathology. OCT has an axial image resolution of ~5-10 um and can image tissue over a much wider area than possible using conventional pinch biopsy. In endoscopic OCT, imaging can be performed over several square centimeters of the lumen. OCM has transverse resolutions of 1-2 um and can provide 3D image information at the cellular level. Swept source / Fourier domain OCT/OCM using compact VCSEL (vertical cavity surface emitting lasers) promises to enable imaging with significantly higher imaging speeds than existing commercial OCT technology. We propose to develop a swept source imaging engine which achieves an axial scan rate of 1 MHz, ~40x faster than commercial ophthalmic OCT instruments (25 kHz axial scan rate). Furthermore, swept source OCT/OCM using VCSEL technologies can be engineered into a compact imaging engine which is smaller than a laptop computer. The development of a high performance OCT/OCM imaging engine for the OEM market will enable access to the technology by a wide range of both established and start-up medical companies. This development strategy, which contrasts with focusing on commercialization for a single clinical application, reduces risks and will accelerate the development and impact of the technology across a broad range of clinical applications for cancer imaging. This proposed effort builds upon advances in semiconductor materials technology and tunable lasers developed by Praevium Research, Inc. in NCI grant 4R44CA101067 and follow-on commercial investment by commercial partner, Thorlabs, Inc., the world's largest manufacturer of research OCT technology. This work involves a collaboration between the primary organization Praevium Reseach, Inc. commercial partner Thorlabs, and the OCT group at the Massachusetts Institute of Technology, who was responsible for the invention and development of OCT. PUBLIC HEALTH RELEVANCE: This effort is expected impact public health by advancing a new clinical tool capable of three dimensional in-vivo volumetric imaging of tissue pathology without the need for tissue excision and processing as in conventional excisional biopsy and histopathology. This tool employs advanced high resolution, high data rate optical coherence tomography (OCT), which measures backscattered echoes of reflected light, in the same way that ultrasound imaging measures sound echoes, but with an imaging resolution 10-100 higher than ultrasound. The proposed instrument operates at 40X the imaging speed of existing commercial OCT instruments, and is enabled by a new compact rapidly swept laser source.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

19 SBIR/STTR records share this UEI (2003–2024). Reported award amounts total $13,646,438. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, Department of Agriculture, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.