SBIR/STTR Research Award

Expired CO2/O2 Analysis to Diagnose Pulmonary Embolism

Award identifier abfed0bb89f5b48418f7db1d5b56d31a434dd5e34f738aa239322f183112fb6eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,996

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BREATHQUANT MEDICAL SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2006-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): A rapid, noninvasive, and accurate, point-of-care device to diagnose and exclude pulmonary embolism (PE) remains an unmet need, especially for patients with conditions that activate inflammatory and coagulation pathways and therefore predispose to PE. These conditions include surgery, cancer, age >70 years, prolonged hospitalization, hemodialysis, connective tissue and infectious diseases. In patients with these conditions, the quantitative blood D-dimer assay consistently shows a diagnostic specificity below 25% for PE, thus limiting its usefulness as a rule-out test in the patients who engender the most worry for PE. Although many diseases elevate the D-dimer, few diseases besides PE obstruct blood flow to large volumes of alveoli. The novel diagnostic device, the Carboximeter(r), measures the effect of high-ventilation, low-perfusion mismatch from PE on the composition of exhaled breaths. The central hypothesis states that the instantaneous ratio of the expired partial pressure of CO2/O2 at the end of the alveolar phase of steady- state tidal breathing (Carboximetry(r)) will accurately discriminate patients with PE from patients who have other conditions that mimic PE. Three prior clinical trials of 370 patients (n=77 PE+) have demonstrated that the CO2/O2 ratio >0.45 has diagnostic sensitivity and specificity at least equivalent to the quantitative D-dimer 0.45 or a D-dimer 98% and specificity >50%. These highly feasibly specific aims will provide background data needed to establish Carboximetry as a viable alternative or adjunct to the D-dimer to screen for PE in high-risk patients. The condition of clots in the lung, termed pulmonary embolism (PE), is the second leading cause of sudden, unexpected death in the U.S. Physicians lack a quick, accurate method to diagnose and exclude PE at the bedside, especially in patients at risk for PE. This project will fund a clinical study designed to test the diagnostic accuracy of a hand- held breath device that detects the altered gas exchange physiology caused by PE in post-surgical and other patients at high risk for PE.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.