SBIR/STTR Research Award

Dramatic Improvements to the Doubly Labeled Water Technique by Measurement of 17O

Award identifier 0b3fb71159b47fdffb65575532a3efeecccb012ab865993ef39f9a841f59ec4dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$149,406

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Los Gatos Research
Proposal award date
Not reported
Contract end date
Not reported
UEI
MYRGAPL7LDK6
Solicitation number
PA10-050
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): The high prevalence of obesity in the US is a major public health concern, as overweight and obese individuals are at increased risk for many chronic diseases. Obesity stems from an imbalance between total caloric consumption and total energy expenditure (TEE), therefore accurate measurements of TEE play a pivotal role in understanding and ultimately reversing this epidemic. The gold standard for measuring TEE in free-living individuals is the doubly labeled water (DLW)method. The major limitations of the DLW method include high cost and precision of only 1 5% for individual measurements. In this Small Business Innovative Research (SBIR) project, Los Gatos Research (LGR) will develop, fabricate, and test a novel, laser-based analyzer to dramatically improve DLW measurements of TEE by concurrently measuring 17O/16O to correct for natural isotopic fluctuations in 18O and 2H. The Triple Isotope Water Analyzer (TIWA), which will be based on LGR's patented, laser-based Off-Axis ICOS technology, will be capable of real-time, simultaneous, high-throughput (50 samples/day) monitoring of 2H/1H, 18O/16O, and 17O/16O in H2O from human bodily fluids (e.g., blood, urine, and plasma), with a target accuracy of better than 10.60 for 2H/1H, 10.20 for 18O/16O, and 10.30 for 17O/16O at natural isotopic abundances. For enriched body waters that have been labeled with 2H and 18O, the target accuracy will be comparable to isotope ratio mass spectrometry and better than 11.50 for 2H/1H, 10.50 for 18O/16O. The TIWA will allow quantification of isotopic background fluctuation during measurements of TEE, eliminating the significant constant background assumption made during DLW experiments. Measurement of the isotopic background fluctuation will allow for much smaller isotopic doses to be used, substantially reducing the cost of TEE measurements. Alternatively, these measurements can be used to significantly increase the accuracy of the DLW technique, introducing the possibility of extending this technique from population studies to the accurate assessment of the TEE of individual subjects. During Phase I, LGR will work with Professor Edward Melanson, an established researcher of metabolic studies, and Professor John Speakman, a key developer of theDLW method, to demonstrate a prototype instrument for measurements using vacuum-distilled, clinical samples. The correlation in background fluctuations between 2H/1H, 18O/16O, and 17O/16O from 40 humans will be quantified to demonstrate the applicabilityof using the 17O/16O signal to correct for background fluctuations in DLW experiments. Finally, two individuals will be measured using the DLW method to directly compare the conventional double isotope measurement to the newly-developed triple isotope measurement. At the conclusion of this research project, LGR will have demonstrated the use of the TIWA for DLW measurements and empirically determined the improvement in TEE accuracy and reduction in the DLW method cost due to the measurement of background fluctuation using 17O/16O. PUBLIC HEALTH RELEVANCE: The high prevalence of obesity in the US is a major public health concern, as overweight and obese individuals are at increased risk for many chronic diseases. Obesity stems from an imbalance betweentotal caloric consumption and total energy expenditure, therefore accurate measurements of total energy expenditure (TEE) play a pivotal role in understanding and ultimately reversing this epidemic. This Small Business Innovative Research (SBIR) project will allow direct quantification of isotopic background fluctuation during doubly-labeled water measurements of TEE, potentially reducing the cost of isotope dose for TEE measurements from approximately 400 to 80 per adult subject and thereby greatly increasing the application of TEE measurements for obesity studies.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

160 SBIR/STTR records share this UEI (1994–2013). Reported award amounts total $47,120,524. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: National Aeronautics and Space Administration, Department of Defense, Department of Energy, National Science Foundation, Department of Health and Human Services, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.