SBIR/STTR Research Award

Active Distributed Electrode Array Network for Electrical Stimulation Therapy

Award identifier 2fdc53118d8d22aa6e6473c0a5da0539035cd9d1df228ccf899cd3ed7c1e3379Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$99,510

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CUSTOMKYNETICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Transcutaneous electrical stimulation applications involving high numbers of stimulated muscles have been an area of growing interest in recent years. customKYnetics has been approached in recent months by research groups and stimulation application developers requesting high channel count stimulation devices for use in their spinal cord injury rehabilitation research studies and products. Existing devices do not offer the features and/or number of stimulation channels required for these applications. Such high channel count devices are often cost prohibitive due to the size and complexity of the stimulator and the limited market for any particular configuration. Devices that are available lack the technological capability to coordinate the activity of the electrode pairs in an application-specific manner. Such applications have also lacked clinical acceptance because managing the large number of wires has been burdensome and impractical. We propose the novel Active Distributed Electrode Array (ADEA) technology that solves these problems by allowing the outputs of the applicants 2-channel stimulation unit to be shared thereby forming a stimulator with an essentially unlimited number of virtual stimulation channels. Virtual channels can be added or removed simply by connecting additional low cost, modular 'stimulation nodes'. Nodes will be connected to one another in a daisy-chain fashion to minimize burdensome wiring. The CK200 will provide the stimulation control capability to deploy the electrical stimulation modality in any application, no matter the complexity. This technology will enable, improve efficacy of, reduce cost, and improve availability of high channel count stimulation applications for exercise and rehabilitation. The goals of this Phase I SBIR project will be to demonstrate feasibility of ADEA technology through development and bench testing of concept validation versions of ADEA circuits. In Phase II we will develop clinically viable stimulation nodes, application firmware for the stimulation unit, and user interface designs. We will demonstrate efficacy of the technology in one or more high channel count electrical stimulation based exercise and/or rehabilitation applications for individuals with spinal cord injury. We will additionally consider development of an application specific integrated circuit (ASIC) to implement the stimulation node in a small and lightweight package that can be easily donned at the electrode site using either a elastic band or adhesively to the stimulating electrode itself. The target markets for this device would be clinics who serve patients undergoing rehabilitation following spinal cord injury or stroke and electrical stimulation application developers who serve these populations. The target price for the system will be 3000 for an 8-channel configuration. PUBLIC HEALTH RELEVANCE: The proposed work may benefit public health through development of a clinically viable electrical stimulation technology for use in myriad rehabilitation applications. Compared to existing devices and techniques, the technology may improve efficacy, availability, ease of use, and reduce cost of the therapeutic interventions requiring high numbers of muscles to be activated using electrical stimulation in a well controlled / coordinated fashion.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.