SBIR/STTR Research Award

MINIATURIZATION OF CATHETERS AND PRESSURE SENSORS

Award identifier 0e5c5329aef0596faa5349f1d43075e4e4d50363a6f51e13616c46093f671555Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$106,814

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MILLAR INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
JHTFBP2Y23Q7
Solicitation number
Not reported
Topic code
Not reported

Research abstract

This study will investigate the feasibility of developing a miniature catheter, and a high-fidelity silicon pressure sensor to be mounted at the catheter tip, suitable for introduction through the femoral artery of a 20- gram transgenic mouse for measuring blood pressure and rate of change of blood pressure (dP/dt) throughout cardiovascular system. The sensor will have a high frequency response sufficient for accurate reproduction of transgenic mouse blood pressure waveforms, at heart rates of up to 1,000 beats per minute with pressure change rates of up to 20,000 mmHg per second. The proposed sensor will be half the size of sensors currently available to permit collection of data from cardiovascular sits now inaccessible in the transgenic mouse. To determine feasibility, catheters of the required size will e built with modified sensors. Several alternative designs will be tested and data extrapolated to determine solvability of miniaturization issues. Since many forms of heart disease are caused or affected by genetic factors, the transgenic mouse is the research animal of choice. A more complete description of the effect of a single gene on the cardiovascular system would further the search for cultures of these diseases, the leading cause of death in America. PROPOSED COMMERCIAL APPLICATIONS: Transgenic mice are being used by the thousands throughout the world with several mouse colonies having 20,000 or more mice at any one time. We would consider several hundred of these devices being sold a year as being an economic success for this particular device alone. The sensor itself can be used in other devices, such as wireguides, and the potential application for these devices is many tens of thousands per year.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

6 SBIR/STTR records share this UEI (2001–2016). Reported award amounts total $1,470,275. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.