SBIR/STTR Research Award

Haptic Feedback Improvements for Prostheses

Award identifier 414bce337208a8565becdc676f10fb79cf9bbb42c87822ef4de877adede3bf37Awarding agency Department of Education

Award amount

$294,262

Program and phase

SBIR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Education
Branch
Not reported
Recipient company
ORTHOCARE INNOVATIONS LLC
Proposal award date
Not reported
Contract end date
2013-06-30
UEI
MUH9WWET7WA1
Solicitation number
Not reported
Topic code
84.133S-2

Research abstract

This project optimizes haptic system design parameters and more thoroughly evaluates the impact of a vibratory haptic system for prosthetics. Objectives include: (1) building a hardware and software test bed for non-invasive voluntary control of a prosthetic hand with vibratory haptic feedback, (2) optimizing the tactor application, (3) assessing the effectiveness of tactor vibratory feedback on cognitive loading interpretations, and (4) assessing perceptions of subjects regarding the actual use of haptic feedback. Specifically, Objective One involves the construction of a controlled box. Fingertip sensors on the thumb and index finger of a myoelectric arm convey pressure data to a microprocessor. Using a mapping algorithm, the processor generates a corresponding waveform that is sent to feedback devices (tactors) placed on the skin of the upper arm. Objectives Two through Four test the vibratory feedback on seven below-elbow amputees. Objective Two determines the best tactor location, vibration waveform, and time duration until deterioration in skin sensitivity occurs by measuring how well the subjects can sense a change in vibration frequency (as identified in previous work as a spectrum of interest). This information assists in determining when a resting period from vibrotactile stimulation is required to avoid over-stimulation of the skin. Objective Three tests the ability of the vibrotactile feedback to provide information on grasping force with the myoelectric hand. The myoelectric hand is controlled by the contraction intensity of the wrist extensor and flexor muscles as detected by electromyography electrodes. Trials use the myoelectric hand to grasp a plush ball at forty percent, sixty percent, and eighty percent of the subject’s maximum grasping force. Trials using vibrotactile feedback, visual feedback, and no feedback are compared. Objective Four requires the subjects to rate the system in terms of level of comfort, accuracy, user friendliness, level of discomfort, and overall usefulness in grasping activities.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

24 SBIR/STTR records share this UEI (2007–2023). Reported award amounts total $12,179,925. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Education, Department of Defense

Agency intelligence

Department of Education

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.