SBIR/STTR Research Award

Time Resolved Ocular Fluorometer

Award identifier 60d3c648e704afd206bea4f91ae90b57c1e50e07014e3ff56e918c7d9c6b6178Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$981,600

Program and phase

SBIR · Phase II

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Ocumetrics Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
X818WECKLP68
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

The goal of this project is to develop a general-purpose instrument for measuring fluorescence lifetimes on and inside the eye. This instrument will take advantage of fluorescence lifetime probes designed for microscopy and analytical chemistry to measure cell volume, oxygen, concentration of electrolytes, pH, and other variables of importance in and on live eyes in animals and eventually humans. This will have obvious applications in eye research and may eventually have applications in disease diagnosis and monitoring. This instrument will also be useful in the measurement of endogenous fluorescence. Thus, autofluorescence of cornea and lens are elevated in diabetes while fluorescent retinal lipofuscins are implicated in the pathogenesis of Age Relate Macular Degeneration. During Phase I, we demonstrated feasibility of this technique in the eye. We have developed a particularly sensitive method for measurement fluorescence lifetimes that is uniquely suited for ocular applications. The eye poses challenges of limited entrance aperture, potential movement, and limited tolerance to light exposure both in terms of intensity and duration. Our overall goal will be to produce a standardized instrument and to develop protocols for making fluorescent lifetime measurements using endogenous or exogenous fluorescent molecules in or on the eye. A critical goal will be standardization and calibration control, so that results made on different machines are comparable. In addition, we will design this instrument with enough flexibility so that we can add capabilities as new fluorescence lifetime probes are developed, and our customers can develop techniques of their own.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

8 SBIR/STTR records share this UEI (1998–2010). Reported award amounts total $4,612,904. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.