SBIR/STTR Research Award

A counterpulsation device to promote myocardial recovery

Award identifier 3fd3018e78480992be5ef1f594108e0be99f5b730a78860d850fbe5971efa50fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$172,749

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SCR, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2006-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The incidence of congestive heart failure (CHF) is increasing worldwide with over one million new cases diagnosed annually. Over the past 30 years, counterpulsation with an intra-aortic balloon pump (IABP) has been widely and successfully used as a short-term treatment for cardiac dysfunction. However, counterpulsation is limited by its location within the descending thoracic aorta to short durations of therapy, typically less than 14 days. To overcome this limitation, Superficial Counterpulsation Research (SCR), Inc. has invented a novel device for long-term application of counterpulsation therapy for heart failure. The counterpulsation device (CPD) is designed to be implanted via a surface operation in the shoulder area (pacemaker pocket) by attaching it to the subclavian artery. This approach would give the patient nearly complete mobility. The first prototype CPD developed was a 40-ml valveless sac that fills and empties with each cardiac cycle. In acute studies in a calf with diminished cardiac function (DCF), the 40-ml CPD successfully reduced ventricular workload and augmented myocardial perfusion. In a cadaver fit study a problem with proper fit of the device in patients was revealed. To solve this problem, a smaller, second generation device (30-ml CPD) was developed. The 30-ml CPD provides a better fit and more comfortable implantation in the shoulder area, but its stroke volume is reduced by 25%, and this change requires verification that it can provide sufficient hemodynamic support. This 30-ml CPD is ready for in vivo testing. The goal of this Phase 1 SBIR proposal is to compare the hemodynamic efficacy of the new, ergonomic 30- ml CPD to the 40-ml CPD prototype. We will also demonstrate that the 30-ml CPD will not damage the artery or blood. This will be accomplished by completing the following specific aims: Aim-1: Demonstrate the efficacy of the 30-ml CPD in reducing ventricular workload and augmenting diastolic perfusion to the heart and vasculature in acute experiments using the DCF calf model. Aim-2: Perform a safety evaluation of the 30-ml CPD by examining possible pathological and hematologic changes in the artery and blood (i.e. hemolysis). In Phase II, we will propose chronic in vivo testing (30-day and 90-day DCF calf model) to demonstrate long-term effectiveness of the 30-ml CPD.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.