SBIR/STTR Research Award

Microfluidic Processing of Leukocytes for Molecular Diagnostic Testing

Award identifier 2735f504a96f8ed9908aba52b78ab92e47fda44850af7c42acea141a38a38706Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$245,048

Program and phase

STTR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
GPB Scientific, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
KVMHTFE6T4K7
Solicitation number
PA12-089
Topic code
NCI

Research abstract

DESCRIPTION (provided by applicant): Microfluidic Processing of Leukocytes for Diagnostics Testing Summary/Abstract: New tests to quantify the numbers and functional states of key leukocyte types from blood samples offer enhanced determination and personalization of clinical diagnosis, prognosis, and treatment response. For example, labeling of gt30 cell surface and intracellular target molecules can assess signaling pathway status of multiple types of normal leukocytes vs leukemia cells simultaneously, bymulti- parameter flow cytometry or in the future, atomic mass spectrometry. However, current procedures to harvest blood leukocytes are expensive, time-consuming, have low cell yields, introduce cytotoxic reagents, selectively lose leukocyte subsets, and require considerable human expertise. Furthermore, multiple sequential steps are required including erythrocyte lysis, surface labeling with monoclonal antibodies (Mabs), fixation/permeablization, and intracellular labeling. Each step requires 1 or more centrifugal wash steps, resulting in cell loss and reduced research productivity. Development of an automated, reagent-free process that ensures high yield of target cells and greatly streamlines the pre-analytical workflow would be a significant benefit to research and clinical labs. Commercial goal: Market a system that combines the harvest, wash and concentration of leukocytes from blood, outperforming standard centrifugal methods. We will apply microfluidic deterministic lateral displacement (DLD), in which the paths cells take through the microfluidic system is based on size and is deterministic, i.e. absolutely determined, not subject to random processes. The key innovation of this STTR project is the use of DLD to remove leukocytes/leukemia cells from erythrocytes and also from labeling or other reagents in a continuous flow process, finally concentrating the target leukocytes/leukemia cells. This is a new use, making this application commercially novel as well as clinically beneficial. The Research Strategy leverages a collaboration among micromechanical systems experts at GPB Scientific LLC; hematopoietic cell biology and cell processing experts at University of Maryland (Civin lab); and microfluidics experts at Princeton University (Sturm-Austin lab). In Specific Aim 1, the team will create microfluidic devices to wash and concentrate leukocytes from a stream containing labeling Mabs in an automated process in a few minutes. In Specific Aim 2, the system will be applied to harvest and concentrate leukocytes labeled in whole blood, removing erythrocytes and unbound Mabs. This project focuses on leukocyte processing for flow cytometry, but the same technology could be used for many existing and new cellular and other (e.g. DNA, RNA) tests for cancer and other diseases. The value proposition is clear: by replacing erythrocyte lysis and centrifugal washing, GPB technology should increase research and clinical productivity through automated, reagent-free workflows that provide high quality cell products, enabling high value cell analyses with reproducible results. PUBLIC HEALTH RELEVANCE: Microfluidic Processing of Leukocytes for Molecular Diagnostic Testing This project is focused on achieving a breakthrough in the sample preparation of leukocytes prior to multi- parameter analysis via flow cytometry. Current methods involving centrifugation are tedious, manual processes that require expert operators and result in lost and damaged cells. Our microfluidic approach will greatly improve cell quality; streamline workflows, and lower costs. Applications include research and clinical diagnostics in cancer, infectious disease, and inflammatory disease, among other disease areas.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2012–2022). Reported award amounts total $4,289,050. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.