SBIR/STTR Research Award

A SIMPLE DEVICE FOR ASSESSING NUTRITIONAL STATUS

Award identifier 96acedb52e4ef8eee5f71bc576e69ef5e90c9ebbff4c73638e1699d359ddd58dAwarding agency Department of Health and Human Services

Award amount

$261,955

Program and phase

SBIR · Phase II

Award year

1985

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
ECO ENERGY CONVERSION
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE USE OF (13)C-LABELED TRACERS IN NUTRITIONAL STATUS ASSESSMENT HAS RECENTLY RECEIVED INCREASED ATTENTION. BREATH TESTS USING LOW-COST (13)C-LABELED TRACERS ARE EMERGING, ALONG WITH BREATH TESTS IN GENERAL IN METABOLIC MONITORING, AS USEFUL CLINICAL TOOLS IN THE STUDY OF NUTRITIONAL DISORDERS IN A MANNER COMPATIBLE WITH AN OUT-PATIENT SETTING. IN SUCH TESTS, THE (13)CO2/(12)CO2 IS MEASURED IN BREATH FOLLOWING (13)C-LABELED TRACER INGESTION: THE RATE AND AMOUNT OF (13)CO2 RELEASE CAN BE USED AS A QUANTITATIVE MEASURE TO DISCRIMINATE BETWEEN NORMALS AND PATIENTS. A LIMITING FACTOR TO THE ROUTINE USE OF SUCH PATIENT-EASY TESTS IS THE ABSENCE OF A CONVENIENT, LOW-COST ANALYTICAL TOOL FOR MEASURING (13)CO2/(12)CO2 IN BREATH. THE PROPOSED PHASE I PROGRAM WILL BE DIRECTED TOWARD PROVIDING THE DATA REQUIRED TO INITIALLY VALIDATE THE USE OF A NEW IR-BASED INSTRUMENT IN DIRECT MEASUREMENT OF (13)CO2/(12)CO2 IN BREATH. THIS NEW RATIO INFRARED SPECTROMETER (RIS) USES A HIGHLY REFLECTIVE LIGHT PIPE AS A LOW VOLUME (5 CC) SAMPLE CELL. THE IR-SOURCE IS DIRECTED AT A SLIGHT ANGLE TO THE AXIS OF THIS LIGHT PIPE; THE LIGHT PIPE THUS ALSO SERVES AS A LONG-PASS WHITE CELL WITHOUT THE BULK AND COST NORMALLY ASSOCIATED WITH SUCH A CELL. A BEAM SPLITTER AND THREE PYROELECTRIC DETECTORS ARE USED IN THE RIS TO GIVE SIMULTANEOUS MEASUREMENT AT (13)CO2, (12)CO2 AND REFERENCE WAVELENGTHS. INITIAL WORK DONE BY TRACER WITH THE RIS HAS SHOWN ITS REPEATABILITY IN SAMPLE MEASUREMENT TO BE 1.3 APE FOR (13)C OVER THE CO2 RANGE OF 2 - 6 VOL . IN PHASE I, THE RIS WILL BE MODIFIED TO PERMIT USE OF A LOW VOLUME (25 CC) GAS SYRINGE AS A SAMPLING DEVICE. USING THIS MODIFIED DEVICE, CORRECTION ALGORITHMS WILL BE DEVELOPED TO ACCOUNT FOR THE OBSERVED NON-LINEARITY IN CO2 RESPONSE; THESE ALGORITHMS WILL BE VARIFIED USING REFERENCE SAMPLES ANALYZED BY A RATIO MASS SPECTROMETER (RMS). INITIAL VALIDATION OF THE RIS AS THE INSTRUMENT OF CHOICE IN BREATH TESTS FOR SCREENING IN NUTRITIONAL STATUS ASSESSMENT WILL BE UNDERTAKEN USING BREATH SAMPLES FROM NORMALS AND PATIENTS. SUCCESSFUL COMPLETION OF PHASE I WILL LEAD TO A PHASE II PROGRAM IN WHICH IN-FIELD RIS VALIDATION IS CARRIED OUT IN COLLABORATION WITH CLINICIANS PRESENTLY EVALUATING BREATH TESTS IN NUTRITIONAL STATUS ASSESSMENT.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.