SBIR/STTR Research Award

Microfabricated Implantable Flowmeter for CSF Shunts

Award identifier a38143e37829ac395bc6692a59a3c1ea8425fbbf193cc186f2f046023950c564Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$324,918

Program and phase

SBIR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Infoscitex Corporation
Proposal award date
Not reported
Contract end date
Not reported
UEI
NJM7E3Y9QXJ5
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): An implantable wireless flow meter is proposed that would enable measurement of the flow of cerebrospinal fluid (CSF) through the ventriculoperitoneal (VP) shunt, currently used to treat hydrocephalus patients. CSF flo w is a key indicator of shunt function, and there is currently no way to measure it in situ, resulting in the absence of clinical methods to directly assess shunt function or to predict its failure. Using MEMS microfabrication methods, the proposed flow me ter will be manufactured at a size small enough to be integratable with implanted VP shunts. The key elements in the flow meter are capacitive structures that change properties with change in CSF flow. Radioactive coupling between the internal passive circ uitry and an external detection circuit allows implantation of the flow meter without the need for implanted batteries or transcutaneous wires. The proposed Phase I project will design and fabricate a set of MEMS flow sensor prototypes, which will then be inspected and bench tested to confirm key parameters. In parallel, the electronic circuitry required to wirelessly interrogate the sensor will be designed, assembled and tested. In order to perform a protocol that calls for testing of the sensor under real istic conditions, a test stand will be constructed that allows precise control of flow. Tests will be undertaken with the flow meter to confirm that it can meet a number of evaluation criteria: measurement range, accuracy, and measurement insensitivity to orientation and ambient conditions. In addition, testing which simulates a working shunt will evaluate the effectiveness of biocompatible coatings in preventing formation of occlusions in the sensor. Upon completion of Phase I, we will have proved feasibil ity of the proposed device. Upon completion of Phase II we intend to have developed a wireless flow sensor that could be included as part of an instrumented VP shunt for the treatment of hydrocephalus. PUBLIC HEALTH RELEVANCE: Every year there are approxi mately 23,000 shunt revisions performed in the U.S., in order to correct the relatively common failure of ventriculoperitoneal (VP) shunts used to treat hydrocephalus patients. However, children are still dying from shunt failure, and studies indicate that earlier detection would save a large fraction of these children. An implantable, wireless CSF flow meter would enable the clinician to monitor shunt function during routine office visits (rather than waiting for the re-appearance of hydrocephalus symptoms ), allowing detection of impending shunt failure, avoidance of lifesaving treatment on an emergency basis, and reduction of mortality associated with VP shunt failure.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

210 SBIR/STTR records share this UEI (1986–2013). Reported award amounts total $64,528,765. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Homeland Security, Environmental Protection Agency, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.