SBIR/STTR Research Award

MINIATURE FABRY-PEROT INTERFEROMETER

Award identifier c410cec0cdbfc986e387a7c0a224fbf477f574ba6aacdd724be5ab49e693aba5Awarding agency National Science Foundation

Award amount

$49,800

Program and phase

SBIR · Phase I

Award year

1990

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
Optisensors Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

A NOVEL APPLICATION IS PRESENTED FOR THE USE OF FABRY-PEROT INTERFEROMETRY AS AN ANGULAR SENSOR. THIS IS PARTICULARLY ATTRACTIVE BECAUSE THE ANGULAR SENSITIVITY OF A FABRY-PEROT INTERFEROMETER IS PROPORTIONAL TO THE WIDTH OF THE ETALON. HENCE, IT CAN BE MADE MORE SENSITIVE BY WIDENING THE ETALON. A 10 MM WIDE ETALON, FOR EXAMPLE, YIELDS A WHOLE FRINGE FOR EVERY 50 MICRO-RADIANS OF CHANGE IN THE ANGLE OF INCIDENCE AT A WAVELENGTH OF 0.63 MICRON. THIS ANGULAR SENSITIVITY CAN BE USED TO MEASURE SECONDARY PHENOMENA THAT INDUCE ROTATION SUCH AS VIBRATION AND ACCELERATION. CONVENTIONAL FABRY-PEROT ETALONS ARE POLISHED SLABS OF GLASSWHOSE FLATNESS AND PARALLELISM ARE MAINTAINED TO A HIGH DEGREE OF TOLERANCE. THIS PROCESS IS COSTLY AND TIME CONSUMING. WE PRESENT AN ALTERNATIVE WAY OF FABRICATING FABRY-PEROT ETALONS WITH THE USE OF WAVEGUIDE MICROFABRICATION TECHNOLOGY. THERE ARE DISTINCT ECONOMIC ADVANTAGES TO THIS APPROACH BECAUSE THE RESULTANT MICRO-SENSOR WILL BE CHEAPER THAN THE CONVENTIONAL ONE WHEN MASS-PRODUCED. WE AIM AT DETERMINING THE EFFECTIVENESS OF THE MICROFABRICATION TECHNIQUES AT PRODUCING SEMICONDUCTOR MICRO-ETALONS WHOSE PERFORMANCE IS COMPARABLE TO THAT OF THEGLASS ONES. LITHOGRAPHIC TECHNIQUES WILL BE USED TO DEFINE THE ETALONS ON THE WAVEGUIDE STRUCTURE. THE NEW CONFIGURATION WILL ALLOW THE ANGLE OF PROPAGATION INSIDE THEWAVEGUIDE TO VARY CONTINUOUSLY SO THAT IT CAN BE USED AS AN ANGULAR SENSOR.

Technology keywords

Not reported

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.