SBIR/STTR Research Award

A Novel Needle-based X-ray System

Award identifier 02aab03a341e828270602751e2f3593017707eb1c3378874607d57d1647650ddAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADVANCED X-RAY TECHNOLOGY, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The main objective of this project is to design, fabricate and experimentally research the application of capillary x-ray optics as a means of elevating the dose rate of the radiation produced by a needle-based x-ray system. The goal is to reach the dose rate of 10 Gy/hour at a distance 5 mm from the pseudo-target. The other objective is to apply capillary x-ray optics to creating a high intensity x-ray source that can produce a narrow (diameter lesser than 1.0 ram) quasi-parallel x-ray beam for possible usage in neurosurgery. The offered x-ray system is based on an insertable needle x-ray source with which the x-ray beam properties such as (energy), intensity (delivery time), and beam orientation (exposure region) could be controlled. To achieve the aims of the project I, we will: (1) design, build and test a capillary x-ray lens, (2) incorporate the capillary lens into an optical collimator, (3) integrate the collimator into a prototype needle-based x-ray system; (3) perform calculations of x-ray dose distribution from the pseudo-target using Monte-Carlo simulation; (4) carry out experiments to characterize dose and dose rate distribution of the radiation produced by the pseudo-target, and (5) measure scattering of a sharply focused x-ray beam in tissue imitating materials. Phase II of the project will be devoted to building an extended energy range (8keV-60 keV), high dose rate x-ray system incorporating new x-ray focusing/collimating optics. A treatment planning system for the needle x-ray device will be developed.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.