SBIR/STTR Research Award

A REAL TIME PARTICLE FALL-OUT MONITOR WITH HIGH MASS SENSITIVITY AND PARTICLE SIZE SEGREGATION

Award identifier b60f2d504e43d9a8f058db31ac06692eeb4f8bf6d12de421920a6bc403d03f0fAwarding agency National Aeronautics and Space Administration

Award amount

$49,855

Program and phase

SBIR · Phase I

Award year

1990

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Aeronautics and Space Administration
Branch
Not reported
Recipient company
Femtometrics, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE SEDIMENTATION OR FALLOUT OF AIRBORNE PARTICLES CAN SERIOUSLY DEGRADE THE PERFORMANCE OF CRITICAL SURFACES ON THE ORBITER AND SPACE-BOUND PAYLOADS. AT PRESENT, THE RECOMMENDED METHOD FOR MEASURING PARTICLE FALLOUT CONTAMINATION IS THE WITNESS PLATE WHICH INTEGRATES THE PARTICLE FALLOUT OVER SEVERAL DAYS. THE PARTICLES AND FIBERS COLLECTED ON THE FILTERS ARE SIZED AND MANUALLY COUNTED USING OPTICAL MICROSCOPY TO DETERMINE THE NUMBER OF PARTICLES-FIBERS PER SQUARE FOOT PER 24 HOURS. THIS METHOD IS TEDIOUS, TIME CONSUMING, AND PROVIDES ONLY INTEGRATED DISTRIBUTIONS WITHOUT THE FINE STRUCTURE OF INDIVIDUAL EVENTS. IT WOULD BE OF GREAT ADVANTAGE IF PARTICLE FALLOUT COULD BE MEASURED IN REAL TIME SO THAT SOURCES OF CONTAMINATION COULD BE IDENTIFIED AND REMOVED IN A TIMELY FASHION. IN THIS SOLICITATION WE PROPOSE AN ADVANCED AND INNOVATIVE APPROACH FOR THE MEASUREMENT OF PARTICLE FALLOUT CONTAMINATION IN REAL TIME, THE ELUTRIATOR QUARTZ CRYSTAL MICROBALANCE (EQCM). THIS INSTRUMENT WILL SEPARATE AIRBORNE PARTICLES ACCORDING TO SPECIFIC AND SELECTABLE CUT-OFF SIZES, COLLECT AND WEIGH THE PARTICLES IN REAL TIME ON A SENSITIVE MICROBALANCE, AND RETAINS THE COLLECTED PARTICLES FOR POST ANALYSIS BY OPTICAL OR ELECTRONMICROSCOPY. THE HIGH MASS SENSITIVITY OF THE EQCM COULD DETECT A SINGLE 25 MU M PARTICLE OF MASS DENSITY 2 G/CM(3).

Technology keywords

Not reported

Agency intelligence

National Aeronautics and Space Administration

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.