SBIR/STTR Research Award

Rapid Real-Time High-Sensitivity Trichloroethylene Vapor Analyzer

Award identifier 319334ccf1b526282884649a1ad483178a9df9c6409afb6292eb8b6a6ab7cc02Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$148,209

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ENTANGLEMENT TECHNOLOGIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
LMYYK99MF117
Solicitation number
PA12-088
Topic code
NIEHS

Research abstract

DESCRIPTION (provided by applicant): This Small Business Innovation Research Phase I project will address the need for a trace trichloroethylene (TCE) vapor sensor. TCE is a toxic volatile organic compound (VOC) used as an industrial solvent. TCE is a common soil contaminant at industrial toxic waste sites, and it migrates through the soil away from the original contamination site. TCE vapor intrusion into buildings from contaminated soil concentrates the TCE vapor indoors, where it poses a health risk to the occupants. Currently, TCE is monitored by capturing it with chemically active materials, and then analyzing those materials in a laboratory; the measurement interval is hours or days. A real-time monitor with a measurement interval of minutes would enable real- time mapping of the TCE concentration within a building, to locate vapor intrusion points of ingress and to monitor the quantity of TCE entering the building. The mapping distinguishes TCE entering the building from indoor sources of TCE. Entanglement Technologies proposes to determine the feasibility of developing a TCE vapor sensor based on the combination of cavity ring-down spectroscopy (CRDS) and diffusion time-of-flight (DiTOF) incorporating stationary phases (as in gas chromatography). CRDSprovides extremely sensitive detection while diffusion with stationary phase provides specificity. The research objective for phase I is to demonstrate selective TCE vapor detection in air in the presence of other VOCs and atmospheric components (such as carbon dioxide and water vapor). The project will comprise building a table-top CRDS/DiTOF prototype gas analyzer to test with TCE and other VOCs. The anticipated TCE sensitivity is 20 parts per trillion by volume in a measurement time of approximately 10 minutes, surpassing existing technologies. The long term objective of this project is to develop a portable TCE vapor analyzer as a commercial product with a 10 pptv sensitivity. An additional objective is to adapt the same basic analyzer design resulting from this project to many different trace gases, including atmospheric and indoor-air pollutants, and combinations of trace gases. Such a family of analyzers will impact pollution research, control, and mitigation as much as CRDS carbon dioxide, methane, and water analyzers are currently impacting the study of greenhouse gases and climate change. As a long term objective, CRDS/DiTOF technology will be applied to biomedical science, industrial process monitoring, environmental remediation and explosives detection. For example, the diffusion-based selectivity will prove critical to the separation and quantification of the many hydrocarbon gas components in human breath useful for non-invasive diagnosis of disease. Similarly, CRDS/DiTOF can enable sensitive chemical analysis of liquids such as blood. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: This Small Business Innovation Research project will address the need for a real-time, trace trichloroethylene vapor sensor to replace or supplement time-integrating sensors. Trichloroethylene, a toxic volatile organic compound, is a common soil contaminant at industrial toxic waste sites, and trichloroethylene vapor intrudes into buildings where it poses a health risk to the occupants. A real-time trichloroethylene sensor would enable mapping of the vapor concentration within a building to locate vapor intrusion points of ingress so that they may be sealed.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2012–2022). Reported award amounts total $2,387,913. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Commerce, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.