SBIR/STTR Research Award

MODULATING REACTIVE SHUNT CIRCUIT CONTINUOUSLY IN INFINITE STEPS IN LIEU OF SWITCHING CAPACITORS. (2) ACCEPTING ALSO NON-SINUSOIDAL WAVE FORM.

Award identifier 26fdc1fa5fd1def17a9527fe0b63329f0313d5f5692e89c9e43f65f3cd0a7887Awarding agency National Science Foundation

Award amount

$40,000

Program and phase

SBIR · Phase I

Award year

1985

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
Queensboro Transformer
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

A SYSTEM FOR AUTOMATIC POWER FACTOR CONTROL IS PROPOSED WHICH MODULATES REACTIVE POWER COMPENSATION. THIS PROPOSED SHUNT SYSTEM COMPRISED A FIXED SIZE CAPACITOR AND A SYSTEM OF COUPLED FIXED RATIO AND VARIABLE RATIO TRANSFORMERS. THEMODULATING CONTROL CAN NOT CAUSE ELECTRIC TRANSIENTS, WHICH ARE AN UNDESIRABLE CHARACTERISTIC OF THE OLD ART OF CAPACITOR SWITCHING. IN THOSE SYSTEMS IN WHICH THE DISTORTED SINE WAVE IS STRONGLY PRESENT, THE WATT LOSS CONTROL ADOPTED BY THIS SYSTEM ASSUMES GREATER IMPORTANCE THAN THE POWER FACTOR CONTROL. THE FACT THAT THERE IS A POSSIBILITY OF HAVING TO DO WITH A DISTORTED SINE WAVE BRINGS THE PROBABILITY OF GETTING INTO RESONANCE IN ONE OF THE HARMONICS, THE 5TH, 7TH, 9TH, OR 11TH. THE AMPLITUDE OFTHE HARMONIC MIGHT BECOME SO SIGNIFICANT THAT IT MAY EXCEED THE ALLOWABLE LIMITS OF THE EQUIPMENT. THAT REQUIRES INSERTION OF A HARMONIC SUPPRESSING REACTOR INTO THE POWER CIRCUIT. THE PRACTICAL SOLUTION SEEMS NOW TO BE A DETECTION SYSTEM FOR DI2/DVAR BEFORE THE CORRESPONDING CURRENT REACHES A HARMFUL LEVEL, AND SUBSEQUENT DISABLING OFTHE PROGRESS OF THE SHUNT DEVICE BY STOPPING THE VARIABLE TRANSFORMER IN THE COMBINATION: VARIABLE TRANSFORMER, FIXED TRANSFORMER, FIXED CAPACITOR. DURING NORMAL OPERATION THE SUPPRESSING REACTOR IS BYPASSED BY A SHUNT CIRCUIT WHICH INCLUDES A CONTACTOR. WHEN SUPPRESSION IS REQUIRED, THE SHUNT CONTACTOR IS OPENED AFTER DISABLING THE VARIABLE TRANSFORMER WHICH INSERTS THE SUPPRESSING REACTOR INTO THE MAIN CIRCUIT. FROM THIS MOMENT ON, THE PROGRESS OF THE VARIABLE TRANSFORMER IS REINSTATED AND CURRENT REACHES THE DESIRED OPTIMUM VALUE. EXPERIMENTAL VERIFICATION OF THIS ISREQUIRED, AND IS AN IMPORTANT COMPONENT OF THE RESEARCH PROGRAM.

Technology keywords

Not reported

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.