SBIR/STTR Research Award

Chelated Lanthanide Emission Fingerprinting for Multiplexed Homogeneous NAT

Award identifier 83b078f6c2f137de061e95bfdefa546a2490695ce370ff9b2300cbbb6cccf13fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$161,087

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
WAVE 80 BIOSCIENCES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
XDG6MCTKJEW7
Solicitation number
PA10-150
Topic code
NIGMS

Research abstract

DESCRIPTION (provided by applicant): Multiplexed homogeneous bioassays provide an important alternative to microarrays for multiplexed analysis of biological samples, because they avoid some of assay development challenges and can greatly reduce assay turnaround time. For simultaneously detecting multiple targets in a homogeneous assay format, target-specific fluorescent labels (in various configurations, such as directly labeling and beacons) are an effective tool. Additional methods for multiplexed homogeneous bioassays, such as the Chelated Lanthanide Emission Fingerprinting (CLEF) method proposed here, would complement fluorescence methods and potentially offer advantages for some applications, such as those where filter wheels or multiple detectors areimpractical due to the size or robustness requirements of the instrument. Multiplexed point of care diagnostic devices are improved by both the rapid turnaround time of homogeneous methods and the potential size and durability improvements achieved by avoiding filter wheels in the proposed multiplexing method. The CLEF assay scheme utilizes the long luminescent lifetimes of chelated lanthanides with molecular beacon technology to provide sensitive, multiplexed detection of nucleic acids. The assay takes place entirely in solution, speeding turnaround time. The CLEF assay uses luminescence-lifetime-based multiplexing; the different target-specific beacons each have different luminescent decay profiles, determined by the chelated lanthanide conjugated to the beacon. All the beacons are excited with a single LED, and all the beacons that are hybridized to their complementary target luminesce, while the energy of those that are not hybridized is quenched by a dark quencher. All emissions are read with a single emission filter and a single detector. The CLEF method is enabled by an instrument with a novel multiplexing algorithm and high-speed optics and data acquisition hardware. The CLEF algorithm separates the luminescent decay into the components contributed byeach beacon, determines which beacons are signaling and which are quenched. In this 6-month R43 Phase I, work is organized around two specific aims designed to demonstrate the feasibility of this novel homogeneous multiplexing approach - Aim 1 establishingthe reporter chemicals and conjugating them to probes, and Aim 2 enhancing the high-speed instrument and extending signal processing algorithms from duplex to greater degrees of multiplexing. 1 PUBLIC HEALTH RELEVANCE Project Narrative Homogeneous bioassays provide several advantages over assays that require the target to diffuse to probes on a planar solid phase, including the rapid turnaround time and simplicity in modeling the system kinetics. However, multiplexing is notoriously challenging in homogeneous bioassays, especially those with instruments suitable for use at the point of care. This proposal focuses on the development of a novel multiplexing method designed for use in homogeneous nucleic acid tests, made possible by novel probes, an advanced detector, and innovative signal processing algorithms. Nucleic acid tests using this multiplexing method can have a rapid turnaround time and can provide information about multiple infectious diseases or genotyping of a single disease, while reducingthe cost per test over single target tests.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

14 SBIR/STTR records share this UEI (2003–2023). Reported award amounts total $6,971,568. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.