SBIR/STTR Research Award

SBIR Phase II:High-K PMN-PT Thick Film With K Above 3000

Award identifier 0b737b9caaecd3cbae64566ff713fb032f03b42820af8b51c6446dac6ab5a06aAwarding agency National Science Foundation

Award amount

$499,997

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
Chemat Technology, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
UBKMTWL8B8D5
Solicitation number
NSF 08-548
Topic code
EL

Research abstract

This Small Business Innovation Research (SBIR) Phase II project aims to develop high dielectric constant (high-K) thick film for high-frequency ultrasonic transducer. Thick piezoelectric film technology is very attractive for the fabrication of thin piezoelectric element in high-frequency ultrasonic medical imaging applications. However, it is challenging to process high-quality piezoelectric film with thickness in the range of 10-20 micrometers. In addition, the film needs to demonstrate dielectric constant of 3000 or higher due to the need of electric matching in fabricating array transducers. In previous Phase I project, a piezoelectric thick film with dielectric constant higher than 3000 was demonstrated. In this Phase II project, the high-K thick film will be utilized to develop miniature high frequency single element and linear array transducers for Intravascular Ultrasonic (IVUS) imaging applications. The broader/commercial impact of this project will be the potential to provide high-K thick film to enable the application of miniature high-frequency ultrasonic transducers. IVUS is a medical imaging methodology using a specially designed catheter with a miniaturized ultrasound probe attached to the distal end of the catheter, which is inserted into the heart or into a coronary vessel for visualizing the vessel and heart structure. This project is expected to further miniaturize the ultrasonic transducer mounted on the catheter and provide improved resolution. With this anticipated catheter, surgeons may view the arteries of patients more clearly and spend less surgery time. Plus, the smaller size will make the procedure less invasive. In addition, this technology can also be used in other applications such as Radio Frequency (RF) filters for cell phone, ultrasonic valve and tuning devices, liquid delivery and droplet ejectors, chemical and biomedical sensors etc.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

77 SBIR/STTR records share this UEI (1992–2013). Reported award amounts total $16,193,218. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Science Foundation, Department of Energy, National Aeronautics and Space Administration, Environmental Protection Agency

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.