SBIR/STTR Research Award
Two Coil Arterial Spin Labeling Cerebral Perfusion MRI
Award amount
$95,000Program and phase
SBIR · Phase IAward year
2001Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- NOVA MEDICAL, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- Not reported
- Topic code
- Not reported
Research abstract
DESCRIPTION (Provided by Applicant): Cerebral blood flow (CBF) defines the rate
of delivery of metabolic substrates and is central to brain metabolism. A
non-invasive method for measuring regional cerebral blood flow is therefore
important for assessing pathologies associated with alterations in cerebral
metabolism such as carotid artery stenosis, stroke, and brain tumors, as well
as for studying mental illnesses and drug abuse. In this study we will develop
and assess the feasibility of a novel MR hardware for regional CBF and
perfusion territory mapping in humans.
The novel Arterial Spin Labeling (ASL) technique for cerebral perfusion and
perfusion territory mapping proposed will build on our preliminary MR
continuous Arterial Spin Labeling (cASL) work which has provided the first
system capable of performing cASL in humans at 3T. To achieve this, we will
validate the feasibility of a method employing a separately gated OW AF source
that can be flexibly interfaced to GE or Siemens scanners and an independently
detunable spin-labeling coil to magnetically label inflowing blood water for
use in conjunction with a detunable head coil to eliminate interactions between
the imaging and labeling systems. The proposed system will improve the MR
perfusion measurements by: 1) Providing a magnetization transfer-free technique
allowing the acquisition of multi-slice, arbitrary plane, quantitative MR
perfusion maps. 2) Improving sensitivity and coverage by covering all of the
major arteries with an efficient labeling coil, thus enabling a multi-coil cASL
method that will label both posterior and anterior circulation at 3T.
Continuous ASL methods has previously been limited to 1 .5T by potentially
unsafe RF power demands. 3) Independently labeling each of the carotid arteries
to allow the mapping of their perfusion territory and assessing collateral
flow.
PROPOSED COMMERCIAL APPLICATION:
Cerebral perfusion measurements by MRI are a relatively new but rapidly growing
method for studying a wide range of disorders that alter local or global cerebral
blood flow. We plan to make the two coil arterial spin labeling system available
for the first time, to the over 200 neuroimaging research sites. We plan to pursue
a clinical product based on the success of the "investigational use only" device.
Technology keywords