SBIR/STTR Research Award

SPINE FUSION SENSOR

Award identifier 8a1d6aaefa3a068cce79144fc83dbfebdc416f3f9cf515f12401d1bb25ae733dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$128,260

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ELECTROSONICS MEDICAL INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Verbatim from Applicant): Spine fusion procedures restore mechanical stability to a spinal column affected by disease or trauma by mechanical integration of two or more vertebrae. Failure to fuse the vertebra, pseudarthrosis, causes post operative pain and complications. On average, the accuracy of non-invasive imaging techniques in diagnosis of spinal pseudarthrosis is in the range of 59 percent to 80 percent. Currently, direct surgical exploration is the only 100 percent reliable fusion-diagnostic method. However, the bending moment carried by the spinal fixation instrumentation during simple flexion-extension tests depends on the stiffness of the fused spine elements. Therefore, by measuring strain in the elements of the spine fixating instrument, the quality of spine fusion can be evaluated as poor fusion transfers measurable strain onto the fixating device whereas full fusion bears most the load and only minor load transfer occurs. To evaluate status of spinal fusion we propose a telemetric, implantable device that consists of: (1) strain gauge sensor attached to the orthopeadic spine fixator; a device routinely implanted during surgery, and (2) passive electronic circuit (no "on board" power source required) for measurement and wireless data transmission to an outside reader. This diagnostic device utilizes established technologies for new applications producing reliable and accurate diagnosis. PROPOSED COMMERCIAL APPLICATION: Over 247,000 fusions and 275,000 discectomies is performed in U.S. each year. Worldwide, the numbers are more than double Market growth for devices used in spine surgery has been estimated at more than 20%, while the growth rate for spine fusion procedures has been estimated at more than 10%. The worldwide spinal fixation devices market reached an estimated $1.1 billion in 1999 and is growing at approximately 15% per year. The designed sensor will result in significant reduction of cost of post surgical follow-ups. Improvement in patient treatment and the reduction of cost will be the major consequences of thisinnovation in spine fusion monitoring.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.