SBIR/STTR Research Award

TUNABLE-WAVELENGTH SCANNING LASER OPHTHALMOSCOPE

Award identifier 9642e6cfaea88d30ae8dbdcc07f3a719d128733c06372bf25cf3132c0382edd6Awarding agency Department of Health and Human Services

Award amount

$500,000

Program and phase

SBIR · Phase II

Award year

1993

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Schwartz Electro-Optics, Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DIAGNOSIS OF EYE DISEASES DEPENDS CRITICALLY ON IMAGING OF THE RETINA AND ITS SUPPORTING VASCULATURE, INCLUDING THE CHOROIDAL BLOOD VESSELS, WHICH MUST BE VIEWED THROUGH THE SENSORY RETINA. WE WILL DETERMINE WHETHER THE DIAGNOSTIC CAPABILITIES OF ONE OF THE NEWEST RETINAL IMAGING INSTRUMENTS, THE SCANNING LASER OPHTHALMOSCOPE (SLO), CAN BE ENHANCED BY THE USE OF NEAR-INFRARED, WAVELENGTH-TUNABLE LASER SOURCE. OUR PRELIMINARY EXPERIMENTS IN COMBINING THE SLO WITH A TUNABLE TI:SAPPHIRE LASER INDICATE THAT CAREFUL WAVELENGTH TUNING SHOULD MAKE IT POSSIBLE TO BETTER CHARACTERIZE SUB-RETINAL STRUCTURES SUCH AS CHOROIDAL VESSELS\IN PARTICULAR NEW VESSELS INDICATIVE OF EYE DISEASE\IN SPITE OF THE OVERLYING RETINAL LAYERS WHICH OBSCURE THIS VIEW AT PRESENT. THE RESEARCH PLAN WOULD INVOLVE INTERFACING A TI: SAPPHIRE LASER, CONTINUOUSLY TUNABLE OVER THE 700-950 NM RANGE, WITH A SCANNING LASER OPHTHALMOSCOPE AND TAKING IMAGES OF THE OCULAR FUNDUS OVER THAT RANGE. THE IMAGES WOULD BE ANALYZED FOR THE PRESENCE OF VASCULATURE AND OTHER DETAIL NOT OBSERVED BY FIXED-WAVELENGTH IMAGING SYSTEMS. IF CLINICALLY SIGNIFICANT RESULTS WERE OBTAINED, THE DEVELOPMENT OF A COMMERCIAL LASER SOURCE WOULD PROCEED IN A PHASE II PROGRAM, AND WOULD BE THE KEY TO A NEW GENERATION OF DIAGNOSTIC INSTRUMENTS.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.