SBIR/STTR Research Award

Low-cost High-performance MALDI-TOF MS and MS-MS

Award identifier 2922d7bb11388c6a60e1ad21cfa2de90da7e2f77b94799a84c055007f231b878Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$105,000

Program and phase

SBIR · Phase I

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VIRGIN INSTRUMENTS CORPORATION
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The goal of this project is to develop a new low-cost MALDI-TOF mass spectrometer that outperforms all existing MS-MS techniques currently employed with MALDI. In the proposed instrument multiple segments of fragment spectra are required to generate a complete fragment spectrum, each segment corresponding to a particular range of the ratio of fragment mass to precursor mass; but unlike earlier post-source decay (PSD) instruments, accurate fragment ion masses may be determined simultaneously for fragments present due to many of the precursor ions in the spectrum. Thus although 10-15 segments may be required to generate a complete fragment spectrum, 100 or more precursors can be fragmented without sacrificing sensitivity or mass accuracy. A pulse rate of 5 kHz is employed, allowing data to be acquired much faster than in existing TOF instruments typically limited to rates of 200 hz or less. The emphasis is on optimum performance in MS-MS mode, but resolving power and mass accuracy in reflector MS mode are comparable to the best currently available in commercial instruments. Either positive or negative ions can be measured in both MS and MS-MS modes. The unique features of the proposed instrument include simultaneous acquisition of fragment spectra from a large number of precursors, rapid and sensitive precursor and neutral loss scans with high resolving power and mass accuracy, and acquisition of multiplexed MS3 spectra. The design effort is focused on simplicity, reliability, and minimum cost consistent with high performance. A modular approach is employed where many of the major components are common to a family of systems. Common components include the sample plate handling system with motion control, the laser optics and controls, vacuum system, digitizer and computer, and several electronics modules. A novel method for calibrating fragment spectra is described based on inversion of the equation describing the flight time in a two-stage ion reflector to yield an "exact" equation relating fragment mass to flight time. An important initial effort is focused on validating this approach and determining the fragment mass accuracy that can be achieved. A major portion of the research effort is directed toward developing the software required for processing time-of-fight data to automatically generate fragment spectra from simultaneous measurements on multiple precursors. The software will be extended to generating precursor scans, neutral loss scans, and multiple reaction monitoring with LC separation, and to interpreting MS3 time-of-flight data. The system will be validated for applications to protein identification by MS-MS on tryptic peptides and for quantitative and qualitative measurements on complex lipid samples. The Human Proteome Organization has launched major initiatives focused on plasma, liver, and brain proteomics. The premise of these initiatives is that "A comprehensive, systematic characterization of circulating proteins in health and disease will greatly facilitate development of biomarkers for prevention, diagnosis, and therapy of cancer and other diseases". Omenn, Proteomics 2004, 4, 1235-1240. Progress on these initiatives was presented at the most recent HUPO meeting (Long Beach 2006). While many positive results were presented, an inescapable conclusion based on the lack of agreement among results from different laboratories on identical samples must be that present technology falls woefully short of that required to achieve the stated goals. This project, together with improved separations interfaces being developed in a separate project, will provide essential tools for comprehensive proteomic measurements.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.