SBIR/STTR Research Award

X-Ray Detectors for Synchrotron-Based Structural Biology

Award identifier 345ec4ac2d6b379d14369982ca0a53b7de65e982f9e4766ce00268b5cbb31548Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$0

Program and phase

SBIR · Phase I

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AREA DETECTOR SYSTEMS CORPORATION
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Development is proposed of an x-ray Pixel Array Detector (PAD) consisting approximately of 2,000 x 2,000 pixels to enhance macromolecular crystallographic data collection at synchrotron sources. A PAD consists of an x-ray sensing integrated circuit layer bonded to a pixel electronics layer such that each pixel has its own processing electronics. PADs promise to reduce data collection time by up to a factor of 40 relative to existing detectors while improving data quality. They will have specific capability to: 1) Collect a set of monochromatic data (90 degree rotation) in 18 seconds using the standard oscillation method (0.5 degrees per frame, with exposure time of 100 ms per frame) 2) Collect a set of fine-slice data in 90 seconds with a rotation of 0.05 degrees per frame and with an exposure of 50 ms per frame 3) Collect frames at microsecond exposure time for time-resolved protein Laue diffraction. Research during Phase I of this proposal was successful in identifying a mixed-mode analog/digital pixel architecture best suited for the crystallographic application, as well as demonstrating ways of resolving radiation damage concerns. The input signal is analog integrated onto a capacitor, C(int), by a charge to voltage converter in the charge integrator stage using a structure very similar to the one in the existing APAD designs. The voltage on the capacitor is constantly compared to an external reference voltage, V(ref), via a voltage comparator in the threshold detector stage. When the integrated voltage level reaches the reference voltage, a bit is generated and added into an in-pixel digital counter. The threshold detector then also resets the integration capacitor in the charge integrator stage. Thus, each analog cycle of filling C(int) results in an additional digital "count" in the high-order word stored in the in-pixel digital counter. At the end of the exposure frame, the voltage level remaining on C(int) is digitized, if desired, by an analog-to-digital converter (ADC) at the end of each row of pixels. This digitized value is thus the low-order digital word of the exposure Phase II will involve finalization of the specific pixel layout, fabrication of suitably large-area integrated circuits, assembly and application testing of a full-scale PAD.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.