SBIR/STTR Research Award

Pb-Qdot Direct Gamma Detectors

Award identifier 4e43e69af99f60bfdd61f49bf7f94c6becac40cdcc9ed7bb41239ca06e8168ecAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,862,061

Program and phase

SBIR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Weinberg Medical Holdings
Proposal award date
Not reported
Contract end date
Not reported
UEI
CACBXGF9BC17
Solicitation number
PA10-050
Topic code
NCI

Research abstract

DESCRIPTION (provided by applicant): A critical property of radiation detectors is stopping power, which describes the efficiency of the detector in collecting radiation. In order to minimize patient dose, it is helpful to increase stopping power, since stopping power is inversely related to the dose required for obtaining high-quality patient images. Stopping power is strongly related to the effective atomic number of the detector material. Designers of radiological devices would prefer to build radiationdetectors from materials with very high effective atomic numbers, such as lead. Unfortunately, most elements with higher stopping powers are not good candidates as radiation detector materials, because electrical charges (created by radiation in the detector) cannot be easily moved out of the detector material. As a result, instruments placed outside the detector are unable to measure the charges caused by radiation in the detector material. The process of removing charge from the inside of the detector into the outside world (where that it can be measured) is called charge transport . In Phase I, we showed that it was possible to cut the Gordian knot of detector specification, by separating the goal of creating high stopping power from the challenge of favorable charge transport. This separation was accomplished by creating a matrix in which quantum dots made of high-atomic- number material (i.e., lead sulfide) were interspersed within a silicon matrix. Quantum dots are small collections of atoms that havedifferent electrical properties than the bulk versions of these atoms. We used the high stopping power property of the lead sulfide, and the favorable electrical properties of the quantum dots, to convert radiation into charge with high efficiency. We usedthe silicon matrix to transport the charges effectively from the quantum dots to the surface of the silicon matrix, so that the charges could be amplified and provide strong signals to outside instruments. An additional benefit of using silicon as the host matrix was that we showed we could build circuit elements (e.g., amplifier components) on the same material as the radiation detector. Having demonstrated feasibility, our next goal is to ready the product for commercialization by optimizing detector quality. This project represents the first successful application of nanotechnology to direct-conversion radiation detection. It promises to reduce radiation dose to patients and to lower health care costs. In addition to the diagnostic radiology market, theplatform technology will be useful for homeland security and broad-spectrum surveillance for the consumer and defense markets, with potential cross-fertilization to the solar power industry. PUBLIC HEALTH RELEVANCE: This project represents the firstsuccessful application of nanotechnology to direct-conversion radiation detection. It promises to reduce the radiation doses required to collect high quality images, and to reduce the costs of radiology instrumentation. In addition to the diagnostic radiology market, the platform technology will be useful for homeland security and broad- spectrum surveillance for the consumer and defense markets, with potential cross-fertilization to the solar power industry.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

28 SBIR/STTR records share this UEI (2007–2022). Reported award amounts total $23,808,895. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Commerce, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.