SBIR/STTR Research Award

Fully Automated, High Performance SAW Microsensor Array for Mobile Air Sampling and Chemical Monitoring

Award identifier 6b09d5054f1b6d4414413388be1dcdfd93e37a91b69c58bcf0dcae423a128e82Awarding agency Department of Defense · Defense Advanced Research Projects Agency

Award amount

$368,112

Program and phase

SBIR · Phase II

Award year

1996

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Defense Advanced Research Projects Agency
Recipient company
Microsensor Systems Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

The collection of sufficient quantities of truly representative ambient samples (e.g., air, water) for analysis is a serious problem with any mobile air sampling and monitoring system. There are several ways this problem can be addressed. The approach proposed in tihs SBIR is twofold. First, a chemical detector with very high sensitivity and selectivity will be designed to reduce the volume of sample required. Second, the size, volume, cost, and power consumption will be reduced to the point where it will be feasible to deploy an array of detectors throughouth an area to assure more representative sampling. The chemical detectors will be capable of coninous, automatic, remote operation and will interface with a control/data acquisition network via hardwire or RF communication links. The new, high performance chemical detector will be based on solid state surface acoustic wave (SAW) devices, which are very small, low cost, rugged, low power, and highly sensitive chamical detectors. The practical ilimitation of present SAW sensors is their limited chemical sslectivity. The technical approach of Phase I, therefore, will be make a major improvement in selectivity, specifically by placing a miniature GC column ahead of a muliple SAW sensor array. It is projected that the performance of such a SAW Array/GC unit will approach that of a mass spectrometer, but at a fraction of the size, cost, and complexity. The projected SAW/GC system will also be evaluated for minimum size, weight, cost, complexity, maintenance, and power consumption, as well as transportability. Anticipated Benefits: The new SAW Array/GC is designed specifically to meet US requirements for a small, high performance, highly portable, automatic chemical monitor that can be readily deployed anywhere in the world. However, because of it's unique performance capablities and many palnned user options it is also expected to meet many industrial and environmental chemical detection/monitoring requirements. The SAW Array/GC chemical monitor is thus expected to have a significant commercial market.

Technology keywords

Not reported

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.