SBIR/STTR Research Award

Bi-frequency PC-MUT Co-linear Array for Ophthalmic Imaging

Award identifier 84a267fa2bb501a517449c433c87b56b46485625105fb500ea8964c91f0c588cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$154,690

Program and phase

STTR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Blatek, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-051
Topic code
NEI

Research abstract

DESCRIPTION (provided by applicant): Ultrasound imaging of the anterior segment, posterior segment and the full lens contour is important in diagnosis of glaucoma, cataracts, etc. eye disease, eye surgery guidance and post surgery assessment. High resolution, large field of depth and rapid electronic scanning are necessary to obtain accurate images of eye as a whole. Blatek, NCSU and USC team proposes to integrate the innovative single crystal piezo composite micromachined ultrasound transducer (PC-MUT)technology with the novel concept of bi-frequency co-linear array technology to develop broad band, highly sensitive PC-MUT bi-frequency collinear arrays for advanced ophthalmic imaging. In Phase I, a novel dual-layer, co-linear array interconnect fabrication technique will be developed first, demonstrating the functionality of a low frequency co-linear array (7.5/15 MHz) using diced PMN-PT 1-3 composites. A high frequency (17.5/35 MHz) co-linear array will then be developed using micromachined PMN-PT single crystal 1-3 composites. The prototyped bi-frequency PC-MUT co-linear arrays will be evaluated using phantom wires in terms of beam scanning and dynamic focusing using the USC high frequency linear array imaging system. In Phase II, optimized 192/128-element bi-frequency co-linear arrays will be developed and extensive eye imaging experiments will be performed using the USC digital beamforming system. In Phase III, Blatek and the phase II partners will seek to commercialize this technology. PUBLICHEALTH RELEVANCE: The state of art commercial ultrasonic ophthalmic imaging technologies use 10-20 MHz probes with fixed focus and mechanical scanning to obtain ultrasound images with poor resolution in anterior segments. High frequency UBM is helpfulin obtaining high resolution, but lack of field of depth and still requires mechanical scanning. Annular arrays addressed field of depth concern, but requires mechanical scanning and the resolution needs to be improved. High frequency linear arrays showedhigh resolution in azimuth and field of depth control via electronic scanning, but with poor resolution in elevation axis. To overcome these issues Blatek and the team proposes to integrate the novel piezo-crystal micromachined ultrasound transducer (PC-MUT) technology with the novel bi-frequency collinear array technology to develop broad band, highly sensitive PC-MUT bi-frequency collinear arrays for advanced ophthalmic imaging. The bi- frequency design considers both the high resolution requirements foranterior segment imaging and the field depth requirements for posterior and lens imaging. The novel co- linear configuration allows for electronic scanning and dynamic focusing at both azimuth and elevation directions. The proposed technology will also facilitate improved resolution of imaging and increased field of depth for pre-operative analysis of corrective procedures of the lens. In Phase I, a novel dual-layer, co-linear array interconnect fabrication technique will be developed to demonstrate the feasibility of a 64/64-element 17.5/35 MHz co-linear array for ophthalmic imaging. In Phase II, optimized 192/128- element bi-frequency (17.5/35 MHz) co-linear arrays will be developed and extensive eye imaging experiments will be performed using the USC digital beamforming system. In Phase III, Blatek and the phase II partners will seek to commercialize this technology.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.