SBIR/STTR Research Award

Low Insertion Force Epidural, LIFE System for Controlled Insertion

Award identifier 80ddd540c70fcd41f1ec0ff965ef6e28be9390c5fe8c71060d337a823a89ffa3Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$976,545

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ACTUATED MEDICAL, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
VG84D4KN5LR5
Solicitation number
PHS2010-2
Topic code
NIGMS

Research abstract

DESCRIPTION (provided by applicant: In this Phase II NIH SBIR, the Low Insertion Force Epidural (LIFE) device will be further optimized and efficacy measured on human cadavers and live porcine models. Piezo Resonance Innovations, Inc. successfully designed and demonstrated the Phase I LIFE device insertion tool in various tissue models, including trials by senior anesthesiologists. The Phase II developments will lead to a Phase III human study and commercialization in collaboration with a major medical company. With a global market of epidural kits near 219M, a device that will increase safety and comfort, enhance training, and raise penetration success rate by clinicians has commercial viability. The improvements derived from the LIFE device could allow less experienced providers, such as interventional radiologists or non-anesthesia trained pain physicians, to perform epidural procedures. Epidural anesthesia is a form of regional anesthesia involving injection of drugs directly into the epidural space. Epidural anesthesia is used in 2.4 million births annually in the United States, in addition to a wide range of other pain-management procedures as far up the spine as the neck. The procedure can be unpleasant to the patient and difficult to perform because of the high force levels required to penetrate the supraspinous ligament, interspinous ligament and ligamentum flavum. One of the most common complications is an accidental dural puncture. If the dura is punctured accidentally, the chance for a cerebrospinal fluid leak causing a post dural puncture headache is quite high. Headaches can be severe and last from weeks to years. Significant leakage can cause enough intracranial hypotension as to tear veins causing a subdural hematoma, and can cause traction injuries to the cranial nerves resulting in tinnitus, hearing loss, dizziness, facial droop, or double vision. Over-insertion is even more dangerous for epidurals inserted in the neck. The LIFE device will enable the clinician a more controlled entry into the epidural space, eliminating the excessive force that results in 'over-shooting' and dural punctures. This Phase II project will advance a commercially viable LIFE System to aid penetrating the ligamentum flavum, while also minimizing dural puncture wet taps during epidural insertion procedures. PUBLIC HEALTH RELEVANCE: Epidural anesthesia insertion is a difficult procedure, due in large part to the force required to insert a needle through tough ligament and muscle, and into the epidural space. When the needle 'pops-through' the tougher tissue into the epidural space, it is difficult to control the depth of penetration. An error in the procedure is referred to as a 'wet-tap' or dural puncture. The puncture may cause cerebrospinal fluid to leak into the epidural space, often resulting in a post dural-puncture headache and other painful complications. The development of a low force epidural insertion tool will provide clinicians with improved control to decrease pop-through and minimize dural puncture. This new technique will also enhance resident training, and with a reduction in risk, may allow less experienced providers, such as interventional radiologists or non-anesthesia trained pain physicians, to perform epidural insertion. For 2008, the global market for epidural kits is projected to be 219M.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

53 SBIR/STTR records share this UEI (2008–2024). Reported award amounts total $43,582,989. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Defense, National Aeronautics and Space Administration, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.