SBIR/STTR Research Award

Integrated Image-Guided RF Ablation for Liver Tumors

Award identifier d25e178891bf9d272125231c29b75365223000e3b27a48094f275a3ed441e316Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$298,266

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Traxtal, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The goal of this project is to facilitate accurate positioning of radiofrequency (RF) ablation probes during liver tumor treatment. The system developed will integrate pre-procedural CT imaging with electromagnetic device tracking. New methods of soft tissue registration and soft tissue motion compensation will be combined with a versatile RF probe tracking device and computer guidance software. This will enable interventional radiologists to accurately position and reposition RF probes. More accurate placement, positioning, and repositioning of probes responds to a clinical weakness of existing RF ablation techniques and should provide improved outcomes for this rapidly expanding and minimally invasive cancer treatment. The specific aims of the proposal are: 1. Develop an integrated system to provide accurate guidance for RF probe placement based on preprocedural CT images. The integrated system will include: a. Son tissue registration using electromagnetically tracked catheters & guidewires b. Intravascular soft tissue dynamic referencing using electromagnetically tracked catheters c. Accurate delivery ofRF energy using an electromagnetically tracked RF ablation probe 2. Characterize the system accuracy in phantom studies. The accuracy of the system will be evaluated in a liver/respiratory motion simulator. We will determine the simulated clinical accuracy with various levels of respiratory motion effects. 3. Conduct feasibility studies in four swine by inserting the registration and dynamic referencing targets into the hepatic vein via an internal jugular puncture. We will then target percutaneously implanted simulated lesions using a tracked RF ablation probe. The procedure accuracy will be evaluated by measuring the distance of the RF needle probe tip from the planned target using biplane fluoroscopic images.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.