SBIR/STTR Research Award

Microarray based STR genotyping utilizing RecA-mediated ligation

Award identifier 70e13a07f44c116112fedd97ac11d3ffc72448e9fa5b7dcefa4d1ffd1a864145Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$798,103

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
GENE CHECK, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
NCU7WK8LZK77
Solicitation number
PHS2010-2
Topic code
NHGRI

Research abstract

DESCRIPTION (provided by applicant): Tandem repeat sequences (STR) are distributed widely in the human genome. These sites exhibit high levels of length polymorphism as a result of their relative instability during DNA replication, i.e., the tendency for slippage to occur between the template and newly synthesized strands causing deletion or addition of repeat units. Changes in STR repeat number can lead to heritable genetic predispositions and disease. However, their variability makes them ideal markers for genetic studies. One class, the microsatellites containing 4 base pair repeat units, has been selected by the FBI as the basis for a genetic identification system, termed CODIS. Current analysis systems require a 1-2 day assay and employ electrophoretic separation of DNA fragments that contain the STR locus for accurate sizing and identification of the repeat number. The long-term goal of this project is to develop a simple, cost-effective and automatable assay system for STR analysis that allows human identification in less than 3 hours from sample to result by avoiding the need for PCR amplification, target DNA denaturation and electrophoretic separation. In Phase I of this proposal a single locus (TPOX) was used to demonstrate that accurate microarray based STR analysis is technically feasible and sufficiently rapid. In Phase II we will expand this assay to include at least 6 other CODIS loci, convert the technology from an in solution to an immobilized format and attempt to increase assay speed and convenience further by eliminating the PCR step. Our approach to achieving these goals utilizes Gene Check's RecA mediated ligation (RML) technology in which the extreme precision of RecA mediated homology searching in double stranded DNA is used to catalyze specific base pairing of oligonucleotide probes at the STR locus with subsequent ligation into specific products that reflect the length of the STR locus. Gene Check has discovered that RML can operate efficiently when one of the oligonucleotides is immobilized to a microarray slide, making high order multiplexing of the RML-STR technology feasible and practical. Signal amplification methods will be employed to allow genotyping directly from double stranded genomic DNA. Success in this project will produce an STR panel that can immediately be used in forensic applications as well as in human paternity and identity testing. The RML-STR system can readily be adapted to livestock, companion animal and wild animal parentage and identity testing and has potential application to diagnosis of medical conditions related to microsattelite sequence expansion. PUBLIC HEALTH RELEVANCE: Gene Check proposes to utilize its RecA mediated ligation technology for STR genotyping (RML-STR) in a microarray format to allow robust, rapid, low cost and automated STR genotyping. This system will be useful for personnel identification in everyday police investigations as well as in a variety of other forensic and non-human identification applications. Medical applications include tissue typing and genetic analysis of triplet repeat associated disorders.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (1997–2010). Reported award amounts total $1,550,106. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.