SBIR/STTR Research Award

Narrowband Terahertz Imager

Award identifier 757ecbd5589b82e36265ee14f87854596d078b2d01137b104fef623d96175258Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$184,745

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
STI OPTRONICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
KP6VEC6HAVZ7
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Narrowband Terahertz Imager for Nonmelanoma Skin Cancer Detection Terahertz (THz) radiation is nonionizing and safe for probing human tissue. Unlike ultrasound, THz light is capable of submillimeter resolution and, unlike other imaging techniques, THz light is not affected by light scattering. This unique capability has given rise to a number of potential applications for THz light in medicine and bioscience. Realization of these applications has been hampered because existing THz sources generally have low output power, some have limited tunability, and many emit broadband radiation, which can be unsuitable for certain applications. Researchers at the University of California at Los Angeles (UCLA) have demonstrated a new scheme for generating powerful, narrowband, and tunable THz light that can satisfy the needs of these applications. In order to develop this scheme into a practical technology, we are proposing to focus on one specific, highly promising application - an imaging system for detection of basal cell carcinoma (BCC). Nonmelanoma skin cancer is the most prevalent form of cancer affecting over 1 million people per year. Preclinical tests have shown the ability to detect BCC with THz light because BCC tissue tends to have higher water content than normal tissue and THz light is strongly absorbed by water. However, current THz-based diagnostics rely on relatively weak broadband THz sources and require many minutes to create an image of the skin via raster scanning. During scanning the affected skin area must be pressed against a quartz plate, which precludes diagnosing the face and neck. False-positive results are also possible because inflamed normal tissue adjacent to the BCC can strongly absorb THz light. Hence, a more discriminating, more rapid, and noncontact THz-based diagnostic is needed. The overall goal of our program is to develop a narrowband, high-peak-power THz imaging system based upon the UCLA work that 1) is powerful enough to obtain 2-D images without the need for raster scanning with the specimen placed on a quartz plate; and 2) will use its narrowband capability to enable unambiguous detection of the carcinoma in a manner that is not possible with a broadband THz source. During Phase I, we will utilize the UCLA THz source, which has limited tunability, to perform proof-of- principle experiments to demonstrate THz imaging of water phantoms. During Phase II, a higher average power and highly tunable narrowband THz source will be built and used to demonstrate improved detection of BCC. Medical research collaborators will be involved during the Phase II tests. PUBLIC HEALTH RELEVANCE: Narrowband Terahertz Imager for Nonmelanoma Skin Cancer Detection Nonmelanoma skin cancer is the most prevalent form of cancer affecting over 1 million people per year. A new type of skin cancer diagnostic is being developed that will make it easier to identify cancerous tissue and will aid the surgeon during removal of the skin cancer to ensure all the cancer is excised while minimizing removal of healthy tissue. This diagnostic will also be useful as a new tool for medical and bioscience research.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

27 SBIR/STTR records share this UEI (1993–2021). Reported award amounts total $8,008,167. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Defense, Department of Health and Human Services, Department of Agriculture, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.