SBIR/STTR Research Award

Wireless Multi-Modal Brain Monitoring

Award identifier 40589b710fbebea0d32f012f80a1e02df2b2d1f5f53efee4bf950c917ddc63abAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$992,495

Program and phase

SBIR · Phase II

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ITN ENERGY SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
PPC3ZC9W3NJ3
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Over the last two decades, there has been a growing need to record electrical signals directly from the brain in humans and animals, especially in candidate patients requiring resective epilepsy surgery. At the same time, there is an increasing demand for real-time monitoring of a larger number (gt200 channels) and different types of electrodes and modalities to provide adequate spatial and temporal resolution for pathophysiology; a challenge that becomes self-limiting and intractable with current state of practice. ITN Energy Systems, in collaboration with Yale University Epilepsy Program and Ad-Tech Medical Instruments Corporation will bring their unique expertise in biocompatible materials and sensors, nanoscale electronics, neurosurgery, neuroscience, and manufacturing, marketing and commercialization of brain implantable electrodes to develop an enabling wireless, multi-channel intracranial electroencephalogram (icEEG) implantable system/device. In the Phase I effort, we were able to successfully design and fabricate an implantable icEEG measurement and recording device. Successful operation of the device was validated as a free-standing system and then subsequently implanted in three rodents. The implanted monitoring system measured and recorded icEEG signals over the course of several days, including successful demonstration of remote powering using a radio frequency (RF) inductive link and the wireless transmission of icEEG data with a high bandwidth infrared communications link. The goal of the Phase II project will be to expand the Phase I 5-channel system for rodents into a 64-channel system with continuous icEEG recording (0.1 to 500 Hz at a 1 KS/sec sampling rate) for direct application in humans. In particular, we will 1) Optimize the current inductive RF link (13.56 MHz) and power management circuit design to reduce the footprint of the implant antenna, insure MRI safe operation, and incorporate the option of on-board power storage feature (battery and/or capacitor) for continuous uninterruptible operation, 2) Improve and expand the existing infrared link by developing and implementing software to support an IrDA protocol, 3) Reduce overall footprint by 30% using die level components on a lightweight substrate, 4) Conduct extensive biocompatibility and toxicity testing for short and long term applications, and 5) Conduct thorough rodent tests, using expanded 4 by 8 and/or 8 by 8 electrode grid arrays to optimize performance and robustness of the device. Successful completion of Phase II will validate critical building blocks of a multimodal implantable icEEG system that is inherently expandable to meet the growing needs for hundreds of measurement channels. These advances move the device towards use in patients and subsequent product development and commercialization. PUBLIC HEALTH RELEVANCE: This project proposes the design and testing of a wireless, 64-channel implantable system for the continuous recording of icEEG signals from the brain. Such a wireless system will not only eliminate tethering of patients to EEG equipment but expand the number of channels surrounding the seizure onset region in medically intractable epilepsy patients requiring surgery, monitoring of brain trauma, and the understanding of other neurological disorders. The proposed implantable technology will facilitate the direct access of electrical activity within the brain via wireless transmission of a high resolution, digital data stream that links directly into a portable laptop or waste-worn data storage system.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

96 SBIR/STTR records share this UEI (1995–2016). Reported award amounts total $24,219,549. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Energy, National Science Foundation, National Aeronautics and Space Administration, Department of Health and Human Services, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.