SBIR/STTR Research Award

Sensimmer Virtual Phaco Trainer for Cataract Surgery

Award identifier ec3f85252310453e80048bfff175c6e4d05d4f6bca3425eec1847787d3979f0aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$870,961

Program and phase

STTR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
IMMERSIVETOUCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
NXKTLH27SJK3
Solicitation number
PHS2010-2
Topic code
NEI

Research abstract

DESCRIPTION (provided by applicant): The SENSIMMER Virtual Phaco Trainer for Cataract Surgery is a hardware and software solution aimed at a worldwide market of ophthalmology residency programs (including 118 programs in the US). It is developed by the US small business concern ImmersiveTouch-Sensimmer Inc. (Westmont, IL), in collaboration with the surgery simulation team at the University of Illinois at Chicago (UIC) under PI Prof. Pat Banerjee, president of ImmersiveTouch-Sensimmer. The virtual trainer supports the teaching of cataract surgery by phacoemulsification ( phaco ). Phase I produced a prototype capsulorhexis trainer, now being perfected under an NEI-ARRA supplement. Phase II proposes to create a phacoemulsification trainer and to validate both trainers. Task 1. Validate post-ARRA Phase I capsulorhexis simulator. Validation was not funded in Phase I. Validation aims at showing face, construct, and concurrent validity of capsulorhexis. The scoring system of the capsulorhexis simulator includes the number of separate forceps grabs of the lens capsule membrane during capsulorhexis, the number of hits of the lens with the forceps, and the total time for the capsulorhexis. Qualitative factors such as optimal size and shape of the capsular tear and avoidance of errors such as radial tear, corneal incision stress, and corneal touches have recently been added. A system for scoring live operative performance and relating this to simulator performance still needs to be devised and validated. Task 2. Develop a Phase II capsulorhexis simulator. The Phase I simulator aims to simulate only a single standard case of capsulorhexis for verification. Commercialization will require a Phase II capsulorhexis simulator for individual patient variations. Patient variations can affect the visibility or accessibility of the anterior capsule and the rhexis edge (corneal opacity, vitreous opacity, deep set eye, anterior chamber depth, cortical cataract) as well as the mechanical stability or material properties of the eye and lens capsule (involuntary eye movement, posterior synechia = iris attached to lens, weak zonules, high vitreous pressure, capsular thickness and fragility in young vs. old, calcified plaque on anterior capsule). Task 3. Develop a phacoemulsification simulator. The trainee uses both hands and both feet: right hand = phaco handpiece; left hand = nucleus manipulator; right foot = phaco pedal; left foot = microscope adjustment. Real foot pedals (e.g., Alcon) will be used, and the phaco foot pedal will control three modes of the virtual phaco tip: (1) irrigation; (2) irrigation + aspiration; (3) irrigation + aspiration + ultrasound power. The SENSIMMER will simulate the phaco tip in virtual reality and model the instrument handle by the handle of the SensAble Phantom Omni haptic robot. The trainer will be capable of simulating standard surgical techniques (e.g., phaco chop; divide and conquer) and unusual clinical cases (e.g., weak zonules). The trainee will learn to control the rate of both fluid flow and ultrasonic power. Task 4. Validate the phacoemulsification simulator. Validation will again aim at demonstrating face, construct, and concurrent validity, as defined above. This will require developing scoring systems for both simulated and live phacoemulsification. The scoring system for simulated phacoemulsification will include factors such as total time for the operation, efficiency of instrument tip handling as measured by total tip path length, and appropriate use of phaco power settings to avoid thermal damage to the cornea. PUBLIC HEALTH RELEVANCE: ImmersiveTouch-Sensimmer, Inc. develops innovative augmented virtual reality software SENSIMMER for surgical training of residents in such fields as neurosurgery and ophthalmology. In collaboration with the University of Illinois at Chicago, the Partnership proposes to develop and commercialize its training modules for cataract surgery. Following STTR Phases I and II, the SENSIMMER Virtual Phaco Trainer will include well developed modules for the two most difficult part-tasks of cataract surgery: capsulorrhexis and phacoemulsification.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2008–2012). Reported award amounts total $2,257,647. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.