SBIR/STTR Research Award

Next Generation microCT

Award identifier 8e1d8dc3c540a6536be839401807470e47e7859983701da25ed37fbb81e00ffcAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$578,898

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
GAMMA MEDICA-IDEAS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Commercially available microCT (computed tomography) systems have failed to meet the challenging demands for small animal imaging, beyond the single requirement for good spatial resolution. Specifically, they have failed to take into account that the thousand times smaller volume in mice, compared to humans, is also coupled with ten times faster heart rates, and increased respiratory rates and circulation times. Thus, the currently available systems have been limited to either: (1) in-vivo volume CT, which is primarily useful for co-registration of anatomical and with functional images provided by positron emission tomography (PET) or single photon emission computer tomography (SPECT); or (2) ex-vivo high spatial resolution CT, with sufficient contrast resolution for specimen imaging. However, these commercial systems have all failed to address the significant pre-clinical applications for micro-CT, which require improved tissue contrast, lower dose, and faster acquisition times to allow for dynamic images acquired in small animals and to take full advantage of the use of contrast agents. The goal of this project is to develop a next generation microCT for pre-clinical imaging for drug development and medical research. The system will be designed to provide clinical quality CT images in vivo in mice and rats, with performance specifications optimized to accommodate the demanding requirements of the most critical areas of current medical research. Specifically, the instrument will provide very good spatial resolution, ultra fast frame speeds (< 1 second), and low radiation dose to the subject. This will be achieved utilizing a photon counting mode for x-ray acquisition, instead of the standard current integration mode. The system will be capable of gross energy information and energy binning, and thus will provide "Color-CT(tm)" capability, allowing tissue compositional analysis. To accomplish these advances, the system will feature advanced CdTe solid state detectors, coupled to high speed integrated circuits for signal processing, to achieve performance characteristics not currently possible from conventional technologies used by the major CT manufacturers. In Phase-II, a fast dynamic multi-slice Color-CTTM scanner prototype will be developed, employing multiple detector modules in a novel system design incorporating a very fast x-ray source. This new modality, once established in the microCT marketplace, will undoubtedly translate into human CT scanners, and given the current study volumes of clinical CT, the impact that this project imparts to the field of medical imaging will indeed be dramatic.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.