A High Resolution X-ray Fluorescence Detector

Award identifier b730fa39c7df64cb6fc412daca8a39b85ab58faf81f4277befb9f80257098ff5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$754,788

Program and phase

SBIR · Phase II

Award year

2003

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HD TECHNOLOGIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): It has been repeatedly emphasized in the BioSync Report that the development of better XAS detector systems is critical in solving the problem of detectors lagging behind synchrotron sources. The detector bottleneck encountered is in two areas: one is detector count rate limitation, and the other is its limited rejection rate of background in order to examine very dilute systems. By the development of the multilayer analyzer array detector (MAAD), we effectively increased the count rate, and therefore the efficiency of fluorescence detection. Now, we are proposing to largely increase the rejection rate by developing muitilayer analyzer pair array detectors (MAPAD). Our Phase I project has shown that such a detector can be made with a high rejection rate and a reasonable throughput. With two-stage rejection of primary and secondary multilayers, the rejection rate will exceed 200 times with a 15 to 20% throughput. With 28 double multilayer pairs, the detector will collect close to 2% total solid angle at 6 KeV. The anticipated gain on the effective photon counts will be as high as 40 times on very dilute systems. The detector can be made tunable in a large energy region, and easy to operate. With a flexible design, the detector can perform the pair rejection as well as the single multilayer rejection, just like a MAAD. Thus the detector can cover a large sample dilution range from a few mM down to 20 microM or a few ppm. For trace metal detection, the approachable concentration can go even lower. This kind of sensitivity should enable us to approach new systems, such as the examination of biological relevant metals in vivo as well as very dilute systems in environmental, material, physical and chemical research. The detector has a very good market potential benefiting efficient use of high flux beamlines. By expanding the XAS technique to new systems, the detector can potentially enter into new markets.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.