SBIR/STTR Research Award

Point of Care Device for Molecular Detection of HIV

Award identifier 9f05fe636f697d9da3563590414d8fa18d3ef57b729b7de86244a42dbd42f856Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$299,995

Program and phase

STTR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AC DIAGNOSTICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-124
Topic code
NIAID

Research abstract

DESCRIPTION (provided by applicant): According to recent estimates ~33 million people are living with HIV, with 96% residing in the developing world. While antiretroviral therapy is effective and increasingly available, the standard of care requires periodic monitoring of patients' viral load to individualize treatment and to control the emergence and spread of drug- resistant strains of HIV. Currently, viral-load is most commonly assessed with quantitative PCR-based or branched chain DNA assays, which require expensive equipment, infrastructure, and skilled technicians, which are not readily available in resource-limited settings. As a result, man HIV patients are not subjected to the recommended periodic, viral load testing. AC Diagnostics (ACD), in collaboration with University of Pennsylvania (UPenn), will develop inexpensive, automated, fully-integrated, point of care devices for molecular-based detection and quantification of HIV-1 in blood. The core of the technology is a novel, multifunctional, isothermal enzymatic amplification reactor for nucleic acid detection that utilizes a membrane capture scaffold to isolate nucleic acids from complex samples without prior purification and without a need for elution, thereby greatly simplifying flow control andenabling molecular diagnostic devices that are just slightly more complicated than dipsticks and, yet, have nearly comparable performance of benchtop equipment. Our preliminary experiments indicate that the proposed device can detect as few as 10 HIV copies per sample (i.e., less than 100 copies/ml of blood) in less than 60 minutes. Competing technologies currently under development utilize expensive and complex processors and may be unaffordable in many regions of the world. Phase I will provide proof of concept and target clade B and clade C HIV-1 subtypes. By appropriate selection of primers and without any modifications in hardware, the device can be modified to detect other clades according to the region of use. The proposed technology will also enableearly detection of HIV-1 during the highly contagious pre- seroconversion acute-stage of infection to facilitate early treatment and minimize the spread of the disease (which is particularly important with increasing emphasize on test-and-treat and treatment-as-prevention concepts). Yet another important application is the diagnosis of infection in babies born to HIV-infected mothers since persistent maternal antibody makes traditional testing impossible. Such babies are typically started on therapy without testing, resulting in overtreatment of the majority to save the few infected. Our technology can help prevent unneeded exposure and expense. Although the proposed technology is particularly needed in developing countries, it is anticipated that both the instrumented (quantitative) and qualitative devices will also have market niche in the developed world, especially in places located far from major medical centers; in settings when real-time decisions based on viral load measures may be beneficial, and would likely improve efficiency, patients' convenience, adherence to drug therapy, and enable more timely, treatment decisions. Our devices can also be used for home testing to provide early detection. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: The proposed STTR effort will lead to a new generation of point-of-care (POC), molecular (nucleic acid)-based diagnostic devices that will enable the monitoring of the viral load of HIV in patients undergoing therapy and screening for HIV infection in individuals at risk during the seroconversion period and in babies born to AIDS- infected mothers when antibody tests are ineffective. The proposed device will foster improved healthcare both in resource-poor settings and in developed countries.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.