CLINICAL APPLICATION OF A LASER SCANNING CYTOMETER

Award identifier b2230dffa79d5cc574808b9b9c889b87e28c05757ada3ba790db7ddc30c9c8d9Awarding agency Department of Health and Human Services

Award amount

$678,000

Program and phase

SBIR · Phase II

Award year

1994

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
Compucyte Corp.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

WE HAVE DEVELOPED A COMPUTER CONTROLLED LASER SCANNING CYTOMETER POTENTIALLY CAPABLE OF MEASURING MULTIPLE WAVELENGTH FLUORESCENCE AND MULTIPLE ANGLE SCATTER OF CELLS ON A SOLID SUPPORT SUCH AS A SLIDE, CUVETTE, OR CULTURE PLATE AT RAPID ENOUGH RATES TO PROCESS 10,000 CELL SAMPLES IN TWO MINUTES. IN ADDITION TO THE STANDARD FLOW CYTOMETRY MEASUREMENTS, THIS INSTRUMENT INCLUDES IN ITS DATA LISTS AND IT DISPLAYS INTERCHANGEABLY 1) COURSE MORPHOLOGICAL PROPERTIES, 2) THE EXACT TIME OF MEASUREMENT AND 3) CELL POSITION. SINCE CELL POSITION IS RECORDED FOR EACH CELL, CELLS CAN BE VISUALLY OBSERVED DURING RUNS OR RETROSPECTIVELY, AND CELLS CAN BE REMEASURED MULTIPLE TIMES TO FOLLOW KINETIC PROPERTIES OF SELECTED SUBPOPULATIONS. WE HAVE BUILT TWO DUAL PARAMETER INSTRUMENTS, AND WRITTEN SOFTWARE TO CONTROL THEM AND DISPLAY RESULTS. WE WILL DEVELOP AND EVALUATE TECHNIQUES FOR MEASURING CLINICAL SPECIMENS OF HUMAN CANCER WITH THEM AS A POSSIBLE AID IN DIAGNOSIS AND IMPROVED PROGNOSIS AND TREATMENT. THIS REQUIRES THAT WE SENSITIVELY MEASURE FLUORESCINATED NUCLEIC ACID PROBES OR ANTIBODIES AND SIMULTANEOUSLY AND PRECISELY MEASURE THE FLUORESCENCE OF A DNA STAIN SUCH AS PROPIDIUM IODIDE. PHASE I AIMS ARE TO TEST THE FEASIBILITY OF 1) DUAL FLUORESCENCE MEASUREMENTS ON CLINICAL SPECIMENS OF HUMAN TUMORS IN COMPARISON WITH CONVENTIONAL FLOW CYTOMETRY, AND 2) IMAGING CELLS OR FIELDS AS THEY ARE SCANNED, A) TO CONVENIENTLY SELECT THOSE TO BE MEASURED, OR B) TO VIEW CELLS SELECTED BY THE INSTRUMENT FOR VISUAL CLASSIFICATION.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.