SBIR/STTR Research Award

HOLOGRAPHIC AND REFLECTION X-RAY LASER MICROSCOPE FOR INTEGRATED CIRCUIT INSPECTION

Award identifier 39ca1ca7b0a9c09670a331493600478cf35c79c704e16efcd0f53d09578bcf9aAwarding agency Department of Energy

Award amount

$49,937

Program and phase

SBIR · Phase I

Award year

1990

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Pxl, Inc.orporated
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

WE PROPOSE TO DEVELOP A SYSTEM FOR HIGH RESOLUTION ( 0.05 MU) INSPECTION OF DEFECTS ON RELATIVELY LARGE AREA INTEGRATED CIRCUITS (IC). THE SYSTEM WOULD COMBINE A HIGH RESOLUTION HOLOGRAM (INTERFEROGRAM) OF AN IC WITH A REFLECTION X-RAY MICROSCOPE(1). THE X-RAY HOLOGRAM WOULD ENABLE THE FAST LOCALIZATION OF DEFECTS, AND THE X-RAYMICROSCOPE WOULD PROVIDE A HIGH RESOLUTION IMAGE OF ANY DEFECTS. INITIALLY A SOFT X-RAY LASER, WHICH WAS DEVELOPED AT PRINCETON UNIVERSITY, WILL BE USED AS A COHERENT SOURCE OF RADIATION. HOWEVER PXL IS PLANNING TO BUILD A SMALL (PORTABLE) SOFT X-RAY LASER WITH A MULTILAYER MIRROR CAVITY AND THIS WILL BE USED FOR THE CONSTRUCTION BY PXL OF AN ENGINEERING (COMMERCIAL) DEVICE. THE INSPECTION SYSTEM WILLBE BASED ON THE FACT THAT SURFACES OF DIFFERENT MATERIALS HAVE SIGNIFICANT REFLECTION COEFFICIENTS (UP TO SEVERAL PERCENT) FOR SOFT X-RAY RADIATION IN THE REGION 10-20 NM. THE REFLECTION COEFFICIENT STRONGLY DEPENDS ON THE MATERIAL OF THE SURFACE AND THE ANGLE OF INCIDENCE OF THE RADIATION, THEREFORE GOOD CONTRAST CAN BE OBTAINED FOR LITHOGRAPHIC MATERIALS. THE INSPECTION OF IC WILL CONSIST OF TWO STEPS. IN THE FIRST STEP A HIGH RESOLUTION HOLOGRAM (INTERFEROGRAM)OF A RELATIVELY LARGE AREA OF AN IC WILL BE REGISTERED USINGA CCD DEVICE. THE HOLOGRAM OF THE IC UNDER INVESTIGATION WILL BE COMPARED BY COMPUTER WITH A HOLOGRAM (INTERFEROGRAM)OF A NON-DEFECTIVE IC STORED IN THE COMPUTER MEMORY IN ORDERTO RAPIDLY IDENTIFY AREAS WITH DEFECTS. IN THE NEXT STEP, THESE SPECIFIC AREAS WILL BE IMAGED AT 0.05 MUM RESOLUTION BY THE REFLECTION X-RAY MICROSCOPE. PHASE I WOULD BE DEDICATED TO: THE COMPUTER RAY TRACING, DETAILED ANALYSIS OF NOISE, CONTRAST AND SPECKLE PROBLEMS, AND THE METHODS OF ELIMINATING OR MINIMIZING THESE PROBLEMS,REDUCTION OF DATA TRANSMITTED TO THE COMPUTERS MEMORY AND THE DESIGN OF THE SYSTEM.

Technology keywords

Not reported

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.