SBIR/STTR Research Award

ADVANCED MULTI-CHANNEL RECORDING ELECTRODES

Award identifier 6786d0b058e3bda6868debb8fc6b720d791d56db78e3fae32f8eb3896cd69e87Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$114,991

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Spire Corporation
Proposal award date
Not reported
Contract end date
Not reported
UEI
RG46KJGARZF4
Solicitation number
Not reported
Topic code
Not reported

Research abstract

The overall objective of this program is to use nanostructured porous silicon coatings to enhance the biocompatibility of ceramic-based multi-site neural recording electrode (CBMSE) arrays.Collaborating with K. Moxon of Drexel University, we have already fabricated CBMSE arrays that can chronically record multiple single neuron activity for up to three weeks. However, in order to use these electrodes for long-term studies or as neural interface components of neural prosthetic devices, recordings will have to be maintained for months or even years. We propose to use the porous silicon nanostructures as a scaffold system, attached to the CBMSE array. We anticipate the porous Si scaffold system will a) carry neurotrophic factors to the insertion region of the electrode to minimize neural damage, and b) promote neural growth at the electrode/tissue interface for better contact of the recording sites on the CBMSE array with neurons. To demonstrate the feasibility of this goal in Phase I, Spire, in collaboration with Drexel University, will fabricate single element porous Si-coated CBMSE-based electrodes that will be implanted into a group of laboratory rats and the effect on neural tissue will be evaluated at different time intervals. The neural tissue will be evaluated using histology methods to look for neural damage near the site of implantation and study the growth of neurons into the porous silicon coated electrodes. Dr. M. Frosch, M.D. of Massachusetts General Hospital will assist in interpretation of these histologic findings. In Phase II, upon optimizing the process parameters for producing hybrid porous silicon-CBMSE electrodes, we will design, fabricate and test in-vivo performance of a two dimensional array of this type of electrodes for chronic, long-term (greater than 3 months) multi-site recording.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

429 SBIR/STTR records share this UEI (1983–2014). Reported award amounts total $73,907,551. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Energy, Department of Health and Human Services, Department of Commerce

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.