SBIR/STTR Research Award

VCSEL technology for ultrahigh speed OCT retinal and anterior eye imaging

Award identifier bf88b5a96767bc59b816d3ba581f6f802b61553f3cbdc59ad6f992e39450594dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$999,932

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PRAEVIUM RESEARCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
UEN4RJGPDNR4
Solicitation number
PA11-096
Topic code
NEI

Research abstract

DESCRIPTION (provided by applicant): The ultimate goal of this program is to enable a new generation of high performance, low cost ophthalmic Optical Coherence Tomography OCT technology based on new MEMS-tunable vertical cavity surface-emitting laser (MEMS-VCSEL) swept light sources. This will be accomplished by developing, validating, and commercializing VCSEL technology for swept source OCT (SS-OCT) at 850nm and 1050nm wavelengths used for ophthalmic imaging. This work builds upon strong preliminary datausing optically pumped VCSELs for OCT at both 1310nm and 1050nm obtained by Praevium Research and collaborators at the Massachusetts Institute of Technology (MIT). This prior work has demonstrated numerous performance advantages of VCSELs for SS-OCT imaging. The unique features of VCSELs enable fundamental axial scan rates up to 1MHz, 20-40x faster than current commercial spectral domain OCT (SD-OCT) ophthalmic systems, adjustable sweep rates enabling high speed and long imaging range operating regimes, with imaging ranges gt10x more than commercial SD-OCT ophthalmic systems. These advantages promise to enable a cost-effective, multi-modal OCT instrument capable of retinal, anterior eye and axial eye length imaging. This new generation of ophthalmic technology will enable wide field 3D-OCT retinal imaging for assessing retinal pathology, imaging the anterior eye for improved refractive power measurement, and axial eye length imaging for improved intraocular lens (IOL) implant assessment. The unique performance features of VCSELs will also facilitate functional imaging such as Doppler and polarization-sensitive OCT (PS-OCT). The proposed program will build upon results from optically pumped, amplified 1310nm VCSELs from Praevium Research under a previous NIH-funded effort on VCSELs for OCT cancer imaging, to develop new electrically pumped, high power VCSELs at 850nm and 1050nm for ophthalmic imaging. These advances are made feasible by lower power requirements for ophthalmic OCT and mature Gallium Arsenide materials. A pure electrically pumped VCSEL technology would represent the first monolithic wafer-scale laser source for SS-OCT, significantly reducing the cost of laser sources and OCT systems. This would in turn enable penetration of ophthalmic OCT into newmarkets and clinical settings. These broad goals will be realized by addressing laser development, OCT system development, and clinical system validation. VCSEL performance will be increased by incorporating advanced designs and processing methods, with each generation of VCSELs integrated into ongoing clinical studies with collaborators in retinal, whole eye, and anterior eye imaging. PUBLIC HEALTH RELEVANCE: This effort is expected to impact public health by creating a new high performance, low-cost generation of ophthalmic technology based on Optical Coherence Tomography (OCT) using new tunable vertical cavity surface-emitting lasers (VCSELs). This new technology will enable wide field 3-dimensional retinal imaging for assessing retinal pathology, imaging the anterior eye for improved refractive power measurement, axial eye length imaging for improved intraocular lens (IOL) implant assessment, and new modes of functional eye imaging. Reduced system cost will promote expansion of these capabilities into a broader range of clinical settings.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

19 SBIR/STTR records share this UEI (2003–2024). Reported award amounts total $13,646,438. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, Department of Agriculture, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.